RECORD UK DIRECT 25-03-2019
Page 9
Adjustment of CAN Sensors – All sites are different! It is therefore imperative that the you set up the
individual sensors in compliance with EN16005 and site requirements. As well as the mechanical
adjustments, depth and angle, there are several adjustments to be made via the BDED.
Enter programming mode by holding the Blue button on the processor for 4 Flashes
1.
Select Parameter Sensors:
On Activations you can change the sensitivity, and on the Threshold and side screen you can change
the field of detection.
There are several adjustable parameters for each sensor. Please treat the Activation and safety of each
sensor as separate entities.
AKI = internal activation
SI =internal Threshold safety
sssssafetySafety
SR =RH SIDE SCREEN SAFETY
AKA=External activation
SA= Outer threshold safety
SL =LH SIDE SCREEN SAFETY