background image

 

RECORD UK DIRECT 25-03-2019 

Page 16 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for STA20

Page 1: ...RECORD UK DIRECT 25 03 2019 Page 1 Record STA20 RETRO FIT GUIDE For the BESAM SL500 To be read in conjunction with the quick start manual ...

Page 2: ...sensors etc for compatibility All safety sensors must be cat C or above Please refer to the enclosed quick start guide for basic wiring and set up of the STA20 retrofit kit Retrofit Adaptation Kit For Besam SL500 Approx Fixing Time 2 3 hrs The SL500 series of operators are one of the later generation of sliding door operators The original Motor idler pulley belt belt brackets and processor are all...

Page 3: ...insert are checked and replaced if needed It is recommended that the doors are adjusted and aligned before any equipment is installed Remember A badly running manual door A badly running auto door Commence installation by installing the new motor gearbox to the right hand side of the operator The motor comes with a new mounting bracket this is retained by 2 x existing captive nuts bolt which are i...

Page 4: ...he left hand side of the motor within distance of motor wiring loom and connect motor encoder and if needed the motor lock wires to the processor Check all wiring for correct routing and secure with cable ties where ness Install the BDED in the required place and plug in Your door system is now ready to wire up any sensors Auxiliary Items to Please reference the Quick Start Manual enclosed with th...

Page 5: ...uide is intended for use by trained engineers If you have not had training on the equipment then it is possible to set the doors up unsafely All automatic door installations should be installed and set up to comply with EN16005 Once you have mechanically fitted your SLIDE unit follow this guide ...

Page 6: ... Running parameters And then YES 8 Please wait till the door is fully open 9 IF MOTOR DIRECTION IS INCORRECT EITHER SWAP BELT BRACKETS TO REVERSE DOOR DIRECTION OR CHANGE JUMPER JP4 10 Press and hold the lock symbol until the door is fully closed and the message on screen changes Release 11 The door will re open 12 Press and hold the lock button again until the door is closed Release the button an...

Page 7: ...een safety sensors then Program AUX01 to SIO And then program the SIO configuration for the door to slow into creep mode upon sensor activation 24hour Access Control Switch N O 13A Plug Socket within 1 meter from the door on the right hand side Set Address 0 0 for AKI Before Applying Power Set Address 1 0 for AKA Before Applying Power Screened Cable BDE AND OR Options System 20 requires 2xRIC290 t...

Page 8: ...ual Threshold and Safety AKI Inner Activation AKA Outer Activation SI Inner Threshold Safety SA Outer Threshold Safety Most Situations only call for 1x Dual sensor per side of the operator but you can have 2x per side on wider openings and as such you need to address them E g AKA 1 Outer Sensor 1 AKA 2 Outer sensor 2 AIS290 Side Screen Sensors SL Left hand Side Screen Safety sensor SR Right hand S...

Page 9: ...ogramming mode by holding the Blue button on the processor for 4 Flashes 1 Select Parameter Sensors On Activations you can change the sensitivity and on the Threshold and side screen you can change the field of detection There are several adjustable parameters for each sensor Please treat the Activation and safety of each sensor as separate entities AKI internal activation SI internal Threshold sa...

Page 10: ...N ROW 2 ON ROW 3 OFF If the floor is dark grey or black you may need to remove the X in suppression Below is a guide Birds Eye View Of different Threshold safety Fields you can map To change to the required field map change the corresponding Number Default is 0 E g If you had a narrow door way you may select Map 3 or for No Approach from the Right you select Map 18 FIELD SIZE S Now It Is time to s...

Page 11: ...hold the Record logo for 10 13sec The screen will scroll through various software info followed by the option to reset yes No Upon selecting Yes the doors will come to the closed position and reset After 3sec activate the doors to open so they may go through one learn cycle of open close moves slowly and complete their reset cycle No Reset Operator Yes With this symbol showing it represents the ke...

Page 12: ...RECORD UK DIRECT 25 03 2019 Page 12 ...

Page 13: ...RECORD UK DIRECT 25 03 2019 Page 13 ...

Page 14: ...RECORD UK DIRECT 25 03 2019 Page 14 ...

Page 15: ...RECORD UK DIRECT 25 03 2019 Page 15 ...

Page 16: ...RECORD UK DIRECT 25 03 2019 Page 16 ...

Reviews: