Enter programming mode by holding the Blue button on the controller for 4 Flashes
Param STG
Drive Cycle – Open & Closing Speeds
Drive – Open & Close Collision
Guide to Blue Button – Multiple Use (MF)
No of Flashes
Level
1
Single Impulse – Opens Door
3
Learns door parameters (Calibration Run)
4
Programming mode
5
tests the battery on STA 20
8
Factory standards reset
9
Full Reset -9 flash and then pull the emergency stop OUT then IN
14
Soft reset the same as the Record Logo
BDE – Control Switch
To both Lock and Unlock the Keypad operation:
To reset the door:
Press and hold the Record logo for 10-13sec. The screen will scroll through various software info, followed by
the option to reset
yes / No
. Upon selecting Yes the doors will come to the closed position and reset. After
3sec activate the doors to open so they may go through one learn cycle of open / close (moves slowly) and
complete their reset cycle.
No
Reset Operator
Yes
With this symbol
showing it represents
the key lock is ON
For final exit of the building, place the program
selector into the locked function and when you are
ready to leave press the lock symbol once to give a
single open/close exit.
Once outside, stand clear of the sensors and after
the doors are closed, then set your manual locks.
Remember to unlock manual locks prior to using the
first entry key switch on the outside of the building.