Operation
5
BAL_C127_X_SU_H-B_OFFSET_EN_1V1_REC_121-006454632
21 / 32
5.2
Description of parameters
W = Factory settings:
Basic drive
(FP)
PARAMETER
W
Comment
DRIVING CYCLE
→ Closing speed
18
Driving speed when closing the door.
0 = lowest speed
40 = highest speed
– The maximum reachable speed depends on the driven distance
(door width) and the acceleration setting.
→ Opening speed
20
(36)
Change value to 20 after reset!
Driving speed of the opening door.
0 = lowest speed
40 = highest speed
– The maximum speed reachable depends upon the opening angle
and the acceleration setting.
– DIN: > 1.5 s <4 s
TIME DELAYS OPEN
→ Time delay open
2
Determines the minimum time for which a door stays open after it has
been opened by a type AKA, AKI or automatic triggering signal.
0..20 = 0 to 20 seconds, 1 s increments
21..40 = 22 to 60 seconds, 2 s increments
– The hold-open time starts only after all trigger and safety signals
have been made in the closing direction.
→ Time delay SSK
4
Determines the minimum time for which a door stays open after it has
been opened by a type SSK triggering signal.
0..20 = 0 to 20 seconds, increments 1 s
21..40 = 22 to 60 seconds, increments 2 s
– The hold-open time starts only after all trigger and safety signals
have been made in the closing direction.
NOTICE
The open duration can be reduced when sensors are used which keep the door open, for ex-
ample,
Time delay
.
DRIVE
→ Opening angle
35
The opening angle is read during the learning cycle and corresponds to
the value 40.
0 = minimum opening angle
40 = maximum opening angle
–
DIN
: min. 95°