Operation
5
BAL_C127_X_SU_H-B_OFFSET_EN_1V1_REC_121-006454632
23 / 32
CLOSED
OPENING
OPEN
CLOSING
AKI
X
X
X
X
AKA*
X
X
X
SSK
X
X
X
X
SIO
X
X
X
SIS
X
X
TIPP
* AKA is active as safety device while closing
Continuously open /
OPEN
The door is opened and stays open. If an obstruction stands in the way while opening, the operator
tries another five times within a few seconds to bring the door to the target position. Should the ob-
struction remain, the current position is then validated as the continuously open position.
Locked
The locking is activated in the Locked operation mode.
CLOSED
OPENING
OPEN
CLOSING
AKI
X
X
X
AKA
X
X
X
SSK
X
X
X
X
SIO
X
X
X
SIS
X
X
TIPP
OFF
This operation mode can be used only in the USA. The operator is switched to manual operation
(without configurations). An SSK opening is possible, but only under surveillance because some mon-
itoring functions are disabled. Functions like parameter settings, Flash-update, continue to work.
CLOSED
OPENING
OPEN
CLOSING
AKI
AKA
SSK
X
X
X
X
SIO
SIS
TIPP
BODYG
X
X
RAILB
X
X
RESET
(hidden button between the buttons
and
)
After pressing the
button for approx. 5 seconds, this status message appears on the display:
Press on the button