5.3
Electronic controller BDE-D (Option)
IMPORTANT
The following listed functions can only be checked after learning of running parameters or
after learning of CAN-sensors.
At the same time the addressing of CAN-sensors will be checked.
The BDE-D electronic controller is an easily operated in-
put and output device for the sontrol and adjustment of
door operators. Logically arranged pushbuttons allow in-
tuitive operation and navigation through the operator
specific menu. The LCD with backlight shows data and
information about the door status with symbols and text
messages.
Additional information can be found in the BDE-D
manual.
5.3.1
Adressing of the electronic controller
Installation with 1 BDE-D
Installation with 2 BDE-D
BDE 1
with Bus termination
(rear face)
BDE 2
without Bus termination
(rear face)
5.3.2
Operating modes and behaviour of the door during input signals
Table of signals (X marks a release reaction)
Explanation of the abbreviations see chapter
Abbreviations
Automatic /
AUTO
Normal operation. The door opens and closes automatically, either by triggering of an activation
device or by pushing the door, if the "touch control (push to active)" is active.
CLOSED
OPENING
OPEN
CLOSING
AKI
X
X
X
X
AKA
X
X
X
X
SSK
X
X
X
X
SIO
X
X
X
SIS
X
X
TIPP
X
Manual operation /
HAND
In this mode the operator works as a normal door closer. It is easy to open the door by hand and
closes automatically. The actuating devices connected are ignored.
One-Way /
EXIT
In the One-Way traffic mode, people cannot enter the room from the outside, but can leave it from the
inside.