![Record Power TS200C Original Instruction Manual Download Page 24](http://html1.mh-extra.com/html/record-power/ts200c/ts200c_original-instruction-manual_1426890024.webp)
11. Maintenance
Changing the blade
1. To change the blade; first remove the crown
guard by slackening off the locking screw and
unhooking from the riving knife
Fig.11.1
.
2. Loosen the 3 screws on the table insert
Fig.113
and remove the insert.
3. Remove the sliding table stop and remove the
sliding table
Fig.11.2A/11.2B
to give access to
the extraction panel. Loosen the holding screw
on the extraction panel and pull the panel away
from the blade to create a space between them
Fig.11.5
.
4. Place the tommy bar in the location hole
behind the blade
Fig.11.7
.
5. Using a spanner, turn the nut clockwise to
loosen it. At this point the tommy bar should
have turned with the blade and be tight up
against the spindle housing creating an anchor
to turn against
Fig.11.4
.
6. Remove the nut, washer and bush from the
blade spindle
Fig.11.6
.
NOTE
Take care not to drop the nut down into
the unit.
7. It is now possible to remove the blade from
the spindle
Fig.11.7
.
The blade can now be replaced.
8. Feed the new blade on to the spindle ensuring
that it is seated firmly on the hub.
9. Replace the bush, washer and nut and using
a spanner, turn the nut anti-clockwise to tighten
it. At this point the tommy bar should have
turned with the blade and be tight up against
the spindle housing to create an anchor to turn
against.
10. Replace the table insert and retighten the
screws to hold it in place.
11. Re-fit the sliding table and secure by fitting
the sliding table stop.
Fig.11.1
Fig.11.2A
Fig.11.2B
Fig.11.3
Fig.11.5
Fig.11.6
Fig.11.7
Fig.11.4
Locking screw