1.3 Key Features and Benefits of the HX2
•
The HX2 safety system includes a pressure/temperature (P/T) relief valve, solenoid-
operated, fail-open dump valve, and an automatic fail-closed steam inlet control
valve.
•
Lightweight, compact design fits through standard doorways and freight elevators.
•
High accuracy temperature control of ±4 °F achieved.
•
Continuous forced re-circulation eliminates temperature stratification and ensures a
uniform temperature distribution across all temperature sensors while also reducing
scaling and sediment build-up on the tube bundles in the process.
•
ASME constructed and stamped tank assures safe operation to 150 PSIG.
•
All wetted parts on the heated side are lead-free and comply with NSF Standard 61
and the requirements of the U.S. Safe Drinking Water Act.
•
Support stand can comply with International Building Code (IBC) guidelines for
seismic requirements.
1.4 Materials of Construction
The standard HX2 tank and couplings are 316L stainless steel passivated to ASTM A380
and A967. Piping is carbon steel, welded or threaded as appropriate. All units come with
a flexible insulation jacket conforming to ASHRAE Std. 90.1, and the support stand and
heating bundle head are powder coated for added durability.
1.5 Flow, Pressure, and Temperature Ratings
•
Heated water recovery rate .............................. 5 to 150 GPM
•
Steam supply pressure ..................................... Up to 100 PSIG
•
Cold water inlet pressure .................................. Up to150 PSIG
•
Heated water outlet temperature ....................... Up to 210 °F
•
Design rating .................................................. ASME Boiler and Pressure Vessel
Code “U” stamped
Summary of Contents for HX2 Series
Page 1: ...Installation Operation and Maintenance Manual INSTALLATION OPERATION AND MAINTENANCE MANUAL ...
Page 14: ...SECTION 2 INSTALLATION HX2 SERIES 2 6 THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 17: ...IOM SECTION 3 OPERATION HX2 SERIES 3 3 3 3 System Wiring Diagram Sizes 0630 and 0636 ...
Page 18: ...IOM SECTION 3 OPERATION HX2 SERIES 3 4 3 4 System Wiring Diagram Sizes 0830 Through 1236 ...
Page 39: ...IOM APPENDIX 1 THE CONTROL PANEL HX2 SERIES A 13 THIS PAGE LEFT INTENTIONALLY BLANK ...