A.9 Control Panel Display Menu Listings
–
Main Menu
T
ABLE
A-3 M
AIN
M
ENU
D
ISPLAY
L
ISTINGS
MAIN Menu Listing
Description
Limits / Values
Control Signal
Temperature Controller Output
%
Setpoint
Displays Current Set Point
Deg F
Water Temp Out
Displays Current Water Outlet Temperature
Deg F
BW Temp In
Displays Current Boiler Water Inlet Temperature
Not for Steam heated units
BW Temp Out
Displays Current Boiler Water Outlet Temperature
Go to OPER Menu
For Navigation to Other Menus
n/a
Go to SET UP Menu
n/a
Go to Config Menu
n/a
Go to Sys Overview
n/a
Go to Alarms
n/a
Password Handling
n/a
A.9a Control Panel Display Menu Listings
–
Operator Menu
T
ABLE
A-4 O
PERATOR
M
ENU
D
ISPLAY
L
ISTINGS
OPER Menu
Description
Limits / Values
Setpoint
Edit Set Point
Use for Set Point Selection and Adjustment
Remote Setpoint
Analog Input Signal Mapped to 0-10 VDC or 4-20 Ma
Local Setpoint
Set Point Entered at Panel
Setpoint Type
Default =
LOCAL
,
REMOTE
Uses Input Signal
Go to OPER Menu
Return to Previous Menu
Pump Switch
Set to
ENABLE
for ON
DISABLED
at Shipment
Control Valve Power
Status Display - Normal Status =
ON
OFF
/
ON
Alarm Status
Control Signal
Displays Current Controller PID Output
%
Control Valve 1
Displays Valve 1 Signal (%)
%
Control Valve 2
Displays Valve 2 Signal (%)
Valve 2 Is Optional
Edit Control Valves
To Set Up Valves and Manually Operate
Control Valve 1
To Manually Operate Valve 1
If Override is
ENABLED
Control Valve 2
N/a For HX2 Units
Manual Override
Default is
DISABLED
for Automatic Operation
CV 2 Enabled
Use to
ENABLE
VALVE 2, Default Is DISABLED
Go Back
Return to Previous Menu
Go to Main Menu
Navigation to Other Menus
Edit Control Valves
Use to Set Up Valves and Manually Operate
Control Valve 1
Use to Manually Operate Valve 1
Control Valve 2
N/a For HX2 Units
Manual Override
Default Setting Is
DISABLED
CV 2 Enabled
Use to
ENABLE
VALVE 2, Default Is
DISABLED
Go Back
Return to Previous Menu
Go to Main Menu
Navigation to Other Menus
Summary of Contents for HX2 Series
Page 1: ...Installation Operation and Maintenance Manual INSTALLATION OPERATION AND MAINTENANCE MANUAL ...
Page 14: ...SECTION 2 INSTALLATION HX2 SERIES 2 6 THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 17: ...IOM SECTION 3 OPERATION HX2 SERIES 3 3 3 3 System Wiring Diagram Sizes 0630 and 0636 ...
Page 18: ...IOM SECTION 3 OPERATION HX2 SERIES 3 4 3 4 System Wiring Diagram Sizes 0830 Through 1236 ...
Page 39: ...IOM APPENDIX 1 THE CONTROL PANEL HX2 SERIES A 13 THIS PAGE LEFT INTENTIONALLY BLANK ...