6.1
Weight Calibration
Accurate results from the Weighlog can only be achieved if the calibration
procedure has been carried out carefully and in the correct sequence.
You must set the zero weight of the empty bucket/forks/trailer and a weight
calibration factor, for each channel to be used.
The calibration factor is an arbitrary number relating the hydraulic pressure
(or strain measurement) in the lift system to the load in the bucket. This factor
must be set independently for each vehicle, attachment or trailer and each
channel of the Weighlog.
6.1.1 Display/Change Calibration Factor
6 - Calibration
1.
Select the appropriate channel.
2.
Press and hold the button. The
display will show "
dYn
" or "
StAt
" for 3
seconds, before changing to show the
calibration factor for that channel (fig.
14). The default factor is 1.00
The left hand digit will be flashing.
To change the factor :
3
While holding the button, PRESS
and RELEASE the button to
advance to the digit you want to
change.
01.00, 01.00, 01.00, 01.00
4.
HOLD the button to cycle the
digit from 0 to 9 (fig.15).
01.10, 01.20, 01.30, 01.40
5.
Release the button and the next
digit will flash.
6. Repeat step 4 for other digits (or if you
need to correct a mistake).
Fig. 14
Fig. 15
11