background image

The  front  panel  has  3 buttons.  The  lower  two  are  used  most  often,  while  the

third  button  is  behind  the        logo.  This  button  is  used  to  enter  the

program mode.

Display Units

The instrument can display up to 9999 tons.  If you prefer to work in lbs units,

this option is selectable from the program mode. 
When  set  to  the  "USA"  readout option,  the  display  will  read  up  to  9990  lbs

rounded to the nearest 10 lbs. Above this threshold (e.g. when displaying any

of  the  totals)  the  display  will  alternate  between  "lbs x 1000"  and  any

remainder. The instrument can display up to 99,990 lbs
For example, for a total of 22,563 lbs the display will alternate between :

Overview

Enter Program

Mode

Set empty bucket

weight to zero

Fig.1

Fig. 2

Select Sub-total

channels 1-5 

or

Grand Total 

(Ch. 6)

Channel 

Indicator

                           

    4         

Summary of Contents for Weighlog 2

Page 1: ...TRIBUTOR If unknown then fax 44 0 1453 733311 Copyright RDS Technology Ltd 2001 Our policy is one of continuous improvement and the information in this document is subject to change without notice Che...

Page 2: ..._ 4 Weighing 9 _____________________________________ 4 1 Dynamic Weighing 9 ____________________________ 4 2 Static Weighing 9 _______________________________ 5 Reset Totals 10 _______________________...

Page 3: ...bucket weight can be added to the total for the channel in use and will also be added to the TOTAL channel which accumulates weight from all of the five channels The instrument has an illuminated 4 di...

Page 4: ...ode When set to the USA readout option the display will read up to 9990 lbs rounded to the nearest 10 lbs Above this threshold e g when displaying any of the totals the display will alternate between...

Page 5: ...adverse effect on weighing accuracy NOTE After any major servicing particularly if you have replaced worn components or carried out welding repairs you should re calibrate the weighing system If the...

Page 6: ...the button to cycle through the channels 3 2 Check change weighing mode 1 With the appropriate channel selected press the button The display will show dYn for dynamic weighing mode or StAt for static...

Page 7: ...the bucket through the reference position A single beep will be heard The display will show a value 2 b Static weighing mode Lift the bucket up to the reference position and stop A single beep will be...

Page 8: ...alarm will beep five times and the display will flash 0 00 3 a Dynamic weighing mode Lift the bucket through the reference position A single beep will be heard The display will show a value 3 b Static...

Page 9: ...ss the Remote Enter Button to add the weight to the sub total for the selected channel and to the TOTAL channel 4 2 Static weighing Static weighing requires the load to be lifted or lowered to the ref...

Page 10: ...econds The display will flash 5 times and then go to zero The TOTAL channel is not affected 5 2 Reset Grand Total 1 Select the TOTAL channel 2 Press and hold the TARE button for 5 seconds fig 12 The d...

Page 11: ...r trailer and each channel of the Weighlog 6 1 1 Display Change Calibration Factor 6 Calibration 1 Select the appropriate channel 2 Press and hold the button The display will show dYn or StAt for 3 se...

Page 12: ...ble weigh scales NOTE If you are loading bags of known weight ensure that they are evenly distributed in the bucket or on the pallet 6 Lift the bucket load a number of times and note the weight displa...

Page 13: ...isting factor x true weight Weighlog reading 1 50 x 0 850 1 15 1 1087 4 Re program with a factor of 1 109 So if the Weighlog reading is more than the true weight the factor is decreased and vice versa...

Page 14: ...can be set to suit lbs readout or tons readout 1 Select the TOTAL channel 2 Hold the button The display will show either Eur for tons or USA for lbs fig 16 3 Continue holding the button and press the...

Page 15: ...or a faulty sensor Visually inspect the wiring loom and connections first then if necessary check continuity of the sensor lead wires between the Harting connector terminals labelled LOAD SENSOR and...

Page 16: ...Channel Attachment Trailer Commodity Weighing Mode Cal Factor 1 2 3 4 5 8 Notes 16...

Page 17: ...Issue 4 12 7 01 Re formatted ref UK263 1 DTP 17...

Page 18: ...Your local distributor is 18...