background image

The Weighlog 2 is intended for use on skid-steer loaders, utility tractors with a

loader attachment, wheel loaders, backhoe loaders (loader side only) and gas

powered fork lifts.
It  measures,  displays  and  records  the  net  weight  lifted,  normally  based  on

sensing  the  lift  system  hydraulic  pressure.  Pressures  sensing  is  problematic

on  certain  types  of  equipment  due  to  the  design  of  the  hydraulic system.  In

these instances strain sensing technology may be used instead.
There are 5 individual display channels available. These can be calibrated for

up to 5 different loader attachments, different trailers or different commodities.

Each  channel  will  display  the  net  bucket  weight  lifted  at  any  time.  If  required

the  bucket  weight  can  be  added  to  the  total  for  the  channel  in  use  and  will

also  be  added  to  the  TOTAL  channel,  which  accumulates  weight  from  all  of

the five channels. 
The instrument has an illuminated 4 digit LCD display, 3 front panel switches,

an  external  pushbutton,  and  an  internal  audible  alarm.  An  external  audible

alarm is optional.
The  instrument  is normally  powered  on  via  the  ignition  circuit and  recalls the

function selected when last used.
With  careful  operation,  system accuracy  can be  as good  as ±1% of  full  load

although ±2% is more common in practice. 

Weighlog

readings are not suitable as a legal basis for the sale of goods.

For each channel you can :

  

adjust the Calibration Factor

  

select either static or dynamic weighing mode.

  

set the Zero Weight (Tare).

  

display and add the bucket weight to the sub-total.

  

reset the Sub-total.

  

receive audible alarm confirmation of the tare and loading routines.

Overview

                           

    3         

Summary of Contents for Weighlog 2

Page 1: ...TRIBUTOR If unknown then fax 44 0 1453 733311 Copyright RDS Technology Ltd 2001 Our policy is one of continuous improvement and the information in this document is subject to change without notice Che...

Page 2: ..._ 4 Weighing 9 _____________________________________ 4 1 Dynamic Weighing 9 ____________________________ 4 2 Static Weighing 9 _______________________________ 5 Reset Totals 10 _______________________...

Page 3: ...bucket weight can be added to the total for the channel in use and will also be added to the TOTAL channel which accumulates weight from all of the five channels The instrument has an illuminated 4 di...

Page 4: ...ode When set to the USA readout option the display will read up to 9990 lbs rounded to the nearest 10 lbs Above this threshold e g when displaying any of the totals the display will alternate between...

Page 5: ...adverse effect on weighing accuracy NOTE After any major servicing particularly if you have replaced worn components or carried out welding repairs you should re calibrate the weighing system If the...

Page 6: ...the button to cycle through the channels 3 2 Check change weighing mode 1 With the appropriate channel selected press the button The display will show dYn for dynamic weighing mode or StAt for static...

Page 7: ...the bucket through the reference position A single beep will be heard The display will show a value 2 b Static weighing mode Lift the bucket up to the reference position and stop A single beep will be...

Page 8: ...alarm will beep five times and the display will flash 0 00 3 a Dynamic weighing mode Lift the bucket through the reference position A single beep will be heard The display will show a value 3 b Static...

Page 9: ...ss the Remote Enter Button to add the weight to the sub total for the selected channel and to the TOTAL channel 4 2 Static weighing Static weighing requires the load to be lifted or lowered to the ref...

Page 10: ...econds The display will flash 5 times and then go to zero The TOTAL channel is not affected 5 2 Reset Grand Total 1 Select the TOTAL channel 2 Press and hold the TARE button for 5 seconds fig 12 The d...

Page 11: ...r trailer and each channel of the Weighlog 6 1 1 Display Change Calibration Factor 6 Calibration 1 Select the appropriate channel 2 Press and hold the button The display will show dYn or StAt for 3 se...

Page 12: ...ble weigh scales NOTE If you are loading bags of known weight ensure that they are evenly distributed in the bucket or on the pallet 6 Lift the bucket load a number of times and note the weight displa...

Page 13: ...isting factor x true weight Weighlog reading 1 50 x 0 850 1 15 1 1087 4 Re program with a factor of 1 109 So if the Weighlog reading is more than the true weight the factor is decreased and vice versa...

Page 14: ...can be set to suit lbs readout or tons readout 1 Select the TOTAL channel 2 Hold the button The display will show either Eur for tons or USA for lbs fig 16 3 Continue holding the button and press the...

Page 15: ...or a faulty sensor Visually inspect the wiring loom and connections first then if necessary check continuity of the sensor lead wires between the Harting connector terminals labelled LOAD SENSOR and...

Page 16: ...Channel Attachment Trailer Commodity Weighing Mode Cal Factor 1 2 3 4 5 8 Notes 16...

Page 17: ...Issue 4 12 7 01 Re formatted ref UK263 1 DTP 17...

Page 18: ...Your local distributor is 18...

Reviews: