PRO-SERIES ATHENE - VARIABLE RATE DRILL CONTROL
12
2.5.4 Set Tramline Rhythm
To set the desired tramline rhythm, select the SETUP screen and press the key.
NOTE: Ensure the drill width has been set correctly, otherwise the tramline rhythm will not be calculated correctly.
Figure 5
Depending on the drill/sprayer combo selected, the target no. of bouts can be up to 15, with symmetrical,
asymmetrical left or asymmetrical right rhythm selectable.
Two special asymmetric rhythms can be selected to suit the following drill/sprayer width combinations.
’10-pass’
4m drill/10m sprayer,
6m drill/15m sprayer
4m drill/13.3m sprayer,
6m drill/20m sprayer
’18-pass‘
4m drill/18m sprayer
The tramline sequences (‘L’ – Left, ‘R’ – Right) are as follows:
Bout
10-pass
18-pass
1
2
R
3
L
4
L
5
6
7
L
R
8
9
R
10
11
12
R
13
14
15
16
L
17
18
UK683-05.PCX
Select the sprayer
/spreader width
Select rhythm
Programmed
bout no at start of
the plot.
Symmetrical
Asymmetrical left
Asymmetrical right