background image

WHERE

 

TO

 

INSTALL

 

THE

 

POWER

 

BURNER

 

IMPORTANT:

 

THIS

 

PR

O

 

BURNER

 

IS

 

FOR

 

OUTDOOR

 

USE

 

ONLY.

WARNING 

The

 

power

 

burner

 

must

 

be

 

installed

 

in

 a masonry

 or

 

other

 

type

 

of

 

fireproof surround

.

 

The

 

unit

 

is

 

not

 insulated 

and

 

therefore

 

must

 

be

 

installed

 

or

 

placed

 

with

 

16"

 

– 18” 

of

 

side

 

and

 

back

 

clearance

 

from

 

unprotected

 

combustible

 

materials

 

such

 

as

 

wood,

 

Plastic,

 

or

 

stucco

 

with

 

wood

 

framing.  PLEASE NOT

E

:  if this is not done

,

 the combustible material will catch on fire and

 

potentially damage your house / structure and may cause bodily harm due to the fire.

 Optional

 

insulating

 Line

#LJRSB3 is available.

Do

 

not

 

install

 

this

 

unit

 

under

 

unprotected

 

flammable

 

surfaces.

 

Do

 

not

 

install

 

or

 

use

 

this

 

appliance

 

inside

 

a

 

building,

 

garage,

 

or

 

any

 

other

 

enclosed

 

area.

 

It

 

must

 

not

 

be

 

used

 

in

 

or

 

on

 

recreational

 

vehicles

 

or

 

boats.

 

This

 

is

 

a

 

slide-in

 

unit

 

designed

 

to

 

fit

 

into

 

open-front

 

enclosures.

 

Control

 

panel

 

of

 

the

 

unit

 

is

 

removable

 

for

 

gas

 

hookup,

 

servicing

 

and

 

burner

 

adjustment.

 

Control

 

panel

 

must

 

remain

 

removable

 

after

 

you

 

install

 

the

 

unit.  Do not have this panel sealed for any reason.

 

Important:

 

The

 

lip on the side

 

requires

 

1"

 

(

 2.5 

cm)

 

of

 

countertop

 

on

 

each

 

side

 

and

 

back

 

to 

Support

 

the

 

unit.

 

Note:

 

We

 

recommend

 

you

 

build

 

the

 

enclosure

 

for

 

the

 

power

 

burner

 

6"-12"

 

(15.2

 

cm-

 

30.5

 

cm) 

LOWER

 

than

 

your

 

countertop

This

 

will

 

ensure

 

a

 

safer

 

environment

 

when

 

using

 

tall

 

cooking

 

pots

 

like

 

the

 

turkey

 

fryer,

 

which

 

can

 

hold

 

40lbs

 

of

 

hot  flammable

 

oil.    Please  make  sure  that  

you do not overfill large pots of oil for the oil will spill over and catch on fire. 

Note:

 

This

 

unit

 

should

 

be

 

installed

 

so

 

that

 

it

 

can

 

be

 

removed

 

at

 

a

 

later

 

date

 

if

 

factory

 

service

 

is

 

required.

 

  

ENSURING

 

PROPER

 

COMBUSTION

 

AIR

 

AND

 

COOLING

 

AIR

 

FLOW

 

You

 

must

 

maintain

 

proper

 

air

 

flow

 

for

 

your

 

power

 

burner

 

to

 

perform

 

as

 

it

 

was

 

designed

 

(diagram below)

 

If

 

airflow

 

is

 

blocked,

 

overheating

 

and

 

poor

 

combustion

 

will

 

result.

 

Make

 

sure

 

not

 

to

 

block

 

the

 

1"

 

(2.5

 

cm)

 

front

 

air

 

inlet

 

along

 

the

 

bottom

 

of

 

the

 

control

 

panel

 

or

 

more

 

than

 

75%

 

of

 

the

 

support

 

grid

 

surface

 

with

 

pans

 

or

 

griddles.

 

Note:

 

The

 

1"

 

(2.5

 

cm)

 

front

 

air

 

space

 

allows

 

access

 

to

 

the

 

drip

 

tray.

 

EXHAUST

 

REMOVAL

 

If

 

installed

 

under

 

a

 

patio

 

roof,

 

the

 

cooking

 

grid

 

area

 

should

 

be

 

fully

 

covered

 

by

 

a

 

chimney

 

and

 

exhaust

 

hood.

 

An

 

exhaust

 

fan

 

with

 

a

 

rating

 

of

 

up

 

to

 

1,000

 

CFM

 

(472

 

liters

 

per

 

second)

 

may

 

be

 

necessary

 

to

 

efficiently

 

remove

 

smoke

 

and

 

other Cooking

 

by-

products

 

from

 

the

 

covered

 

area.

 

Installation

 

in

 

fully

 

enclosed

 

patio

 

areas

 

is

 

not

 

recommended.

 

Summary of Contents for PRO RSB3A

Page 1: ...he latest National Fuel Gas Code ANSI Z223 1 NFPA 54 and Natural Gas and Propane Storage and Handling Installation Code CSA B149 1 This appliance and its individual shutoff valves must be disconnected from the gas supply piping system when testing the system at pressures in excess of psig 3 5 kPa This appliance must be isolated from the gas supply piping system by closing its individual manual shu...

Page 2: ...OFESSIONAL BUILDERS INSTALLERS For Safety have inspected by your local city Gas Company and Fire Department before use This is NOT an indoor appliance for outdoor use only Do not install into a combustible cabinet without an insulating liner LJRSB3 CALIFORNIA PROPOSITION 65 WARNING The burning of gas cooking fuel generates some by products which are on the list of substances which are known by the...

Page 3: ...e vapors and liquids 7 DO NOT obstruct the flow of combustion and ventilation air to this appliance Keep the ventilation openings of the cylinder enclosure free and clear from debris 8 Check all gas connections for leaks with soapy water solution and brush Never use an open flame to test for gas leaks 9 Check flexible hoses for cuts and wear that may affect the safety before each use 10 Never use ...

Page 4: ...f countertop on each side and back to Support the unit Note We recommend you build the enclosure for the power burner 6 12 15 2 cm 30 5 cm LOWER than your countertop This will ensure a safer environment when using tall cooking pots like the turkey fryer which can hold 40lbs of hot flammable oil Please make sure that you do not overfill large pots of oil for the oil will spill over and catch on fir...

Page 5: ...10 water column and is for use with L P gas only If unit is NOT supplied with regulator please make sure that all requirements are met for the type of regulator required Use part number RONHK L P GAS SAFETY REQUIREMENT The LP gas supply cylinder must be constructed and marked in accordance with the Specifications for LP gas Cylinders of the U S Department of Transportation D O T or the National St...

Page 6: ...owing a One side of the enclosure shall be fully open or b For an enclosure having four sides a top and a bottom At least two ventilation openings at cylinder valve level shall be provided in the sidewall equally sized spaced at 180 degrees 3 14 rad and unobstructed Each opening shall have a total free area of not less than 1 2 square inch per pound 7 1 cm2 kg of stored fuel capacity and not less ...

Page 7: ... to the cap to the underside of the cap If the disc 1 2 in diameter of the pin is close to the cap then the regulator is set for natural gas If the disc is at the tip of the pin away from the brass cap the regulator is set for system LP application To convert to natural gas remove the plastic conversion pin and invert and replace it back in a manner such that the disc is close to the brass cap For...

Page 8: ...solution of soap and water in a spray bottle 50 solution 2 Confirm that all control knobs are in the off position 3 Turn the main gas supply valve ON 4 Apply the leak test solution by spraying on all of the pipe joints fittings and hose 5 As gas Leak is detected when a There is a faint smell of gas and or b There is bubbles around the connections 6 DO NOT ATTEMPT TO IGNITE THE BURNER 7 Turn off th...

Page 9: ...er to adjacent Vertical combustible construction must be maintained CLEARANCE TO NONCOMBUSTIBLE CONSTRUCTION A minimum clearance of 1 from the back of the Pro Burner Above cooking surface to non combustible construction is required A minimum of 1 clearance to the sides of the Pro Burner above cooking surface to non Combustible construction is recommended NOTE DO NOT USE THIS APPLIANCE UNDER OVERHE...

Page 10: ......

Page 11: ...e removed by using a mild abrasive pad like Scotch Brite with a stainless steel cleaner Use the mildest cleaner and always scrub in the direction of the grain Do not use steel wool to clean the Pro Burner Do not use abrasives on the polished highlights Be extra careful when cleaning around the highlights Metal polisher or mild chrome cleaner can be used to bring back the luster on highlights To to...

Page 12: ...BURNER IF YOU SMELL GAS 2 WARNING IT IS CRITICAL THAT THE GAS BURNERS ARE PROPERLY INSTALLED WITH THEIR ORIFICES INSIDE THE BURNERS AIR SHUTTERS If not properly installed gas may leak outside of the burner that could lead to fire potential damage to your Pro Burner and bodily injury Inspect the gas supply piping or hose prior to turning the gas ON If there is evidence of cuts wear or abrasion it m...

Page 13: ...er Lighting Instructions The burners can be lit manually using a lighted long match taper or long BBQ lighter 1 Push and turn the knob counter clock wise past the CLICK position Hold the knob pushed in for 5 seconds 2 Insert a lit match or BBQ lighter thru the grates and near the top of the burner Once you see or hear a flame you can release the knob NOTE if the burner does not ignite for the firs...

Page 14: ......

Page 15: ... Steel 1 1 21 RSB3A020 Basin Frame Back Connection Board 1 1 22 RSB3A021 Basin Frame Right Side Panel 1 1 23 RSB3A022 Drip tray 1 1 24 RSB1011 Ignition Wire L 240mm 1 1 25 RSB3A023 Ignition Wire L 330mm 1 1 26 RSB3A024 SS Ripple Tube L 325mm Φ9mm 2 2 RSB3A025 Tube Burner Orifice Φ1 8 LP 1 RSB3A026 Tube Burner Orifice Φ3 45 NG 1 28 RSB3A027 Orifice Fitting Nut 1 1 29 RSB3A028 Orifice Mounting Plate...

Page 16: ...ay occur Improper maintenance salt spray chemicals pesticides will effect the look and integrity of the components RCS will not be responsible for any damage caused as a result of not following owner s manual instructions This non transferable warranty is limited to the replacement of original one time defective parts does not include shipping and labor to remove or install replacement parts if ne...

Reviews: