To prevent fire or explosion hazard, DO NOT use or permit sources of ignition in the area
while performing a leak test. Perform leak test outdoors only.
Check to ensure that flexible hoses do not have any cuts and wear that may affect the
safety before each use. Use only replacement regulator specified by the manufacturer
.
1) Prepare a leak testing solution of soap and water in a spray bottle (50% solution)
2) Confirm that all control knobs are in the off position
3) Turn the main gas supply valve ON
4) Apply the leak test solution by spraying on all of the pipe joints, fittings and hose
5) As gas Leak is detected when:
a. There is a faint smell of gas and/or
b. There is bubbles around the connections
6) DO NOT ATTEMPT TO IGNITE THE BURNER
7) Turn off the main Gas Supply
8) Call a Certified/qualified professional to repair the GAS LEAK
9) DO NOT attempt to use the power burner until the leak is fixed.