Basic Troubleshoot  

 

Check if the camera and illuminator are aligned correctly. 

 

 

For Infra-Red illumination, ensure that a Day and Night or Black and White camera is 

used and that the camera switches correctly into night mode.  

 

 

Check camera and lens. Is iris fully open at night and set correctly. Ensure camera is 

fully operational and has correct night time settings and capability. 

 

 

Ensure  correct  illuminator  lens  angle  selected  for  required  distance  –  check  stated 

performance. 

 

 

Check the LED status indicator: if green LED indicator is lit on the bottom of the unit, 

then the unit is receiving power.  

 

 

If powering from PoE, ensure Power Sourcing Equipment (PSE) is suitably rated for the 

VARIO2 IPPOE HYBRID unit – see page 6 for required ratings – and for all 8 size units 

check correct PoE Detection Resistance has been selected – see page 7. 

 

 

If powering from low voltage 24V DC, check voltage applied and that power supply is 

suitably rated for the VARIO2 IPPOE HYBRID unit – see page 6 for required ratings.  

 

 

Check connection and wiring of CAT5 / 6 cable to VARIO2 IPPOE HYBRID. Verify link 

has been established with the router / switch to which the illuminator is connected and 

that the wiring is compatible with T-568B wiring standard. 

 

 

If the illuminators are correctly wired to the network, run the Raytec Discovery Tool and 

try to discover the illuminator on the network.  

 

If the illuminator is discovered and the “State” indicator is grey, this indicates that there 

is  no  communications  with  the  illuminator.  Ensure  IP  Address  and  Subnet  Mask  of 

computer  and  illuminator  are  set  within  the  same  range.  If  not,  alter  IP  address  of 

illuminator  or  Enable  DHCP  on  illuminator  for  automatic  allocation  of  suitable  IP 

address. 

 

Use a Ping command to see if the illuminator and device are on the same network and 

have communication. 

 

 

If still unsuccessful try a different web browser. 

 

 

If unit still cannot be discovered then type default IP address into browser: 192.168.2.80 

 

 

If  no  communication  possible  after  above  steps,  please  contact  Raytec  for  further 

support or consider a Hard Reset of the illuminator. 

 

 

 

Vario2 IPPOE Hybrid Instruction Guide Rev 1.0.0 Short 

 
 
 

Summary of Contents for vario2ip HYBRID

Page 1: ...gle IHD 60 x 25 beam angle IHD Waterproof RJ45 connector Accessories optional 80 x 30 beam angle IHD 120 x 50 beam angle IHD System requirements PC running Windows 7 with IE9 or equivalent and network...

Page 2: ...se appropriate shielding eye protection Risk Group 2 for cornea lens infrared hazard Hazard distance is 2000mm Eye Safety White Light Caution EN62471 Risk Group 2 Classification Possible hazardous opt...

Page 3: ...if low voltage 24V DC operation is preferred The Vario2 IPPOE Hybrid comes with a number of feratures that allow the user to change between the two wavelengths The illuminator has a photocell for auto...

Page 4: ...TTL ve purple TTL GND External Output volt free yellow white CAT 5 Cable for Data and Optional PoE Interchangeable Lensing PoE Detection Resistance Selection Switch Please note base plate has been re...

Page 5: ...Default is IR for P cell senses darkness and WL for Ext Input if active when P Cell senses darkness Ensure PoE equipment or 24V PSU are suitably rated For 8 sized products check PoE detection resistan...

Page 6: ...P address can be altered or DHCP enabled Alternatively type the IP address of illuminator into a web browser default is 192 168 2 80 and use the web interface to manually alter IP address IMPORTANT We...

Page 7: ...ithout boosting the signal Ensure you make a waterproof connection to the RJ45 as shown below Ensure the connector is waterproof and sealed after the connection is made To illuminator RJ45 RJ45 connec...

Page 8: ...rn the power to the illuminator OFF remove the baseplate and access the switch as shown The majority of PSE equipment requires a detection resistance of 24 9K to establish a PoE link Some models of PS...

Page 9: ...angle To alter to any other angle remove the existing lens and insert the required lens which will have its angle indicated on it Ensure the baseplate is securely re attached to maintain waterproof i...

Page 10: ...pole using U bracket provided or dedicated Raytec bracketry Notes Unit can alternatively be powered by 24V DC if required Multi core auxiliary cable also fitted to unit Use for alternative power 24V...

Page 11: ...ould now appear with a valid IP address You can now double click illuminator to navigate to it WARNING Your network must have DHCP capability Manually set the IP address Run Raytec Discovery Tool Sing...

Page 12: ...etwork press Discover and the Raytec Discovery Tool will display a list of illuminators available on the network See instructions above on how to change IP address or enable DHCP in order to allow com...

Page 13: ...d Operator user password Administrator admin password In order to maintain maximum security of your system we recommend you change the passwords at the earliest opportunity for further information ple...

Page 14: ...photocell The External Input will activate the illuminator at 100 NOT soft start for the duration of the input provided the photocell detects it is dark External Output activated by photocell and wil...

Page 15: ...l Output Type of Input Volt Free Trigger State Photocell Only Active State Short Circuit Low Active State Short Circuit Low Photocell Photocell Sensitivity 20 lux Basic Web Page Functionality All web...

Page 16: ...16 User has access to Home Page and Diagnostics pages Administrator has access to all pages...

Page 17: ...rol of illuminator either locally by VMS or HTTP commands Adv Settings Allows for further detailed setup of External Input External Output Photocell sensitivity level and duration of Override Access C...

Page 18: ...rs below Chrome Internet Explorer 1 Hold Ctrl Shift Del keys 2 Change drop down box to the beginning of time 3 Tick Cached images and files ONLY If others are ticked untick 4 Select Clear browsing dat...

Page 19: ...page 6 for required ratings Check connection and wiring of CAT5 6 cable to VARIO2 IPPOE HYBRID Verify link has been established with the router switch to which the illuminator is connected and that t...

Page 20: ...20...

Reviews: