Wiring 

The illuminator is supplied with a terminated CAT 5 cable with a waterproof Ethernet connector 
(supplied loose i.e. not fitted) and an auxiliary multi-core cable. 

Option 1 – Power via PoE 

 

Connect an Ethernet cable (category 5 or better) using the T-568B wiring standard between the 

Power Sourcing Equipment (PSE) and the illuminator.  Ensure that the PSE is sufficiently rated 

to power the Vario2 IPPOE Hybrid device as follows: 

 

Model 

PoE Requirement 

VAR2-IPPOE-hy4-1, hy4-1-C, hy6-1 

IEEE 802.3at (HP PoE) ≥25.5W 

VAR2-IPPOE-hy8-1, hy8-1-C 

4-pair PoE ≥51W 

 
The  CAT5  cable  is  both  the  power  and  data  connection  for  the  illuminator.  The  maximum 
Ethernet cable length is 100m (328 ft) without boosting the signal.  

Ensure you make a waterproof connection to the RJ45 as shown below. Ensure the connector 
is waterproof and sealed after the connection is made. 

 

 

To illuminator                  RJ45-RJ45 connector              To Network

 

Option 2 – Power from 24V DC 

If  using  low  voltage  power,  connect  24V  DC  to  the  red  (+ve)  and  black  (-ve)  cables  of  the 
auxiliary cable. In this case the Ethernet cable is a data connection only. 

For  either  Option  1  or  Option  2  above,  connect  external  input  trigger  and  external  output  as 
required – see table below: 

 

Colour  

Description 

Wire Gauge (AWG) 

Orange 

External Input -Volt free or TTL +ve 

22 

Purple 

External Input -Volt free or TTL GND 

22 

Yellow 

External Output – Volt free 

22 

White 

External Output  - Volt free 

22 

 
WARNING: To maintain the IP rating of the product the multi-core auxiliary cable must be 
waterproofed and terminated appropriately even if it is not in use. 

 

 

Summary of Contents for vario2ip HYBRID

Page 1: ...gle IHD 60 x 25 beam angle IHD Waterproof RJ45 connector Accessories optional 80 x 30 beam angle IHD 120 x 50 beam angle IHD System requirements PC running Windows 7 with IE9 or equivalent and network...

Page 2: ...se appropriate shielding eye protection Risk Group 2 for cornea lens infrared hazard Hazard distance is 2000mm Eye Safety White Light Caution EN62471 Risk Group 2 Classification Possible hazardous opt...

Page 3: ...if low voltage 24V DC operation is preferred The Vario2 IPPOE Hybrid comes with a number of feratures that allow the user to change between the two wavelengths The illuminator has a photocell for auto...

Page 4: ...TTL ve purple TTL GND External Output volt free yellow white CAT 5 Cable for Data and Optional PoE Interchangeable Lensing PoE Detection Resistance Selection Switch Please note base plate has been re...

Page 5: ...Default is IR for P cell senses darkness and WL for Ext Input if active when P Cell senses darkness Ensure PoE equipment or 24V PSU are suitably rated For 8 sized products check PoE detection resistan...

Page 6: ...P address can be altered or DHCP enabled Alternatively type the IP address of illuminator into a web browser default is 192 168 2 80 and use the web interface to manually alter IP address IMPORTANT We...

Page 7: ...ithout boosting the signal Ensure you make a waterproof connection to the RJ45 as shown below Ensure the connector is waterproof and sealed after the connection is made To illuminator RJ45 RJ45 connec...

Page 8: ...rn the power to the illuminator OFF remove the baseplate and access the switch as shown The majority of PSE equipment requires a detection resistance of 24 9K to establish a PoE link Some models of PS...

Page 9: ...angle To alter to any other angle remove the existing lens and insert the required lens which will have its angle indicated on it Ensure the baseplate is securely re attached to maintain waterproof i...

Page 10: ...pole using U bracket provided or dedicated Raytec bracketry Notes Unit can alternatively be powered by 24V DC if required Multi core auxiliary cable also fitted to unit Use for alternative power 24V...

Page 11: ...ould now appear with a valid IP address You can now double click illuminator to navigate to it WARNING Your network must have DHCP capability Manually set the IP address Run Raytec Discovery Tool Sing...

Page 12: ...etwork press Discover and the Raytec Discovery Tool will display a list of illuminators available on the network See instructions above on how to change IP address or enable DHCP in order to allow com...

Page 13: ...d Operator user password Administrator admin password In order to maintain maximum security of your system we recommend you change the passwords at the earliest opportunity for further information ple...

Page 14: ...photocell The External Input will activate the illuminator at 100 NOT soft start for the duration of the input provided the photocell detects it is dark External Output activated by photocell and wil...

Page 15: ...l Output Type of Input Volt Free Trigger State Photocell Only Active State Short Circuit Low Active State Short Circuit Low Photocell Photocell Sensitivity 20 lux Basic Web Page Functionality All web...

Page 16: ...16 User has access to Home Page and Diagnostics pages Administrator has access to all pages...

Page 17: ...rol of illuminator either locally by VMS or HTTP commands Adv Settings Allows for further detailed setup of External Input External Output Photocell sensitivity level and duration of Override Access C...

Page 18: ...rs below Chrome Internet Explorer 1 Hold Ctrl Shift Del keys 2 Change drop down box to the beginning of time 3 Tick Cached images and files ONLY If others are ticked untick 4 Select Clear browsing dat...

Page 19: ...page 6 for required ratings Check connection and wiring of CAT5 6 cable to VARIO2 IPPOE HYBRID Verify link has been established with the router switch to which the illuminator is connected and that t...

Page 20: ...20...

Reviews: