Programming Mode and Operating Mode 

On powering up the illuminator, it automatically enters 

programming mode to allow the user to adjust set-up and 

operation. The programming mode automatically times out after 

7 Days or until the user actively disables the remote control or the 

unit times out 30 minutes after any press of the manual buttons on 

the illuminator. 

During Programming Mode and Operating Mode  the two LED’s 
indicate the following status : 
LHS SOLID GREEN:  

Power Applied 

LHS FLASHING GREEN:  Remote control IR receiver problem (Max 

VRC distance is 8m (26ft) 

RHS FLASHING AMBER:  Indicates unit is in programming mode 

(Programming Mode Only) 

RHS SOLID AMBER: 

 Indicates that a valid command is being 
received from the remote  (Programming 
Mode Only) 

LHS FLASHING RED: 

Voltage supply problem detected 

LHS SOLID RED: 

Illuminator fault detected 

All functions of the remote control and buttons are available in 
Programming Mode.  

The only function of the Remote Control available during 

Operating Mode is LED Status Indicators Enable/Disable, entering 

a PIN or disabling manual buttons (if done at the same time as  

disabling the remote – see P.8) 

Factory Default: On initial power-up, Programming Mode. 

6  

Step 5. Photocell following output (White & Yellow) 
Volt free output - normally open (day) to normally closed (night). 

Connect direct to camera if required to control switchover of day/night 

cameras. 

Step 6. Programme using optional VARIO Remote Control (VRC) or the 

manual control buttons. 

Step 7. Set PIN (If Required) (Can only be done with the optional VARIO 

Remote Control(VRC) 

LED Status Indicators- Feedback system : 

There are two tri-coloured LEDs visible on the base of the VARIO2 

illuminator. The two LEDs provide important operating and status 

information.  

The LED Indicators also give feedback if you are using the 

Remote, PIN Function or Manual Control Modes – Please see 

Pages 10 to 17 for detail on the LED status indicator feedback for 

these functions  

Summary of Contents for VARIO2 VAR2-i2-2

Page 1: ...ed Photocell sensitivity MID Status LEDs ON No PIN Set Unit will change from Programming Mode to Operating Mode after 7 Days or 30 minutes after last press of manual buttons Timer Disabled VARIO2 Spec...

Page 2: ...plate at the bottom of the unit The number of button pushes indicated below are based on the user starting with the illuminator in either programming or operating mode Action Required Step1 LHS Button...

Page 3: ...two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are disabled The only remote control functions that can be used in Oper...

Page 4: ...rmittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down the No of characters required After PIN deleted Illuminator goes to Programming Mode Standard LED indication For full PIN...

Page 5: ...rking Cover photocell fully light should turn on if valid telemetry input It is sometimes difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably...

Page 6: ...eam and 120 beam angle ILS Bracketry VARIO2 Enhancements Increased Distance Default time for illuminator to go into Operating Mode reduced PIN function for enhanced security Manual Control added Push...

Page 7: ...mplete Set up and Installation Step 1 Select different beam angle if required To alter to 10 simply remove interchangeable lens ILS To alter to 60 replace with other ILS lens supplied Other angle ILS...

Page 8: ...control and buttons are available in Programming Mode The only function of the Remote Control available during Operating Mode is LED Status Indicators Enable Disable entering a PIN or disabling manua...

Page 9: ...ble manual buttons must be done within 5 minutes of remote disable 9 Extra VRC Functionality PIN Function For extra security VARIO2 allows a PIN Personal Identification Number to be set for each lamp...

Page 10: ...ough Note invalid characters will not be recognised To create a PIN press STATUS BUTTON for 4 seconds LHS LED will flash RED GREEN This indication will always show that you are in PIN mode RHS LED FLA...

Page 11: ...gs Power Level Photocell sensitivity Indicator LED status On or Off A continuous 4 second press of the LHS button turns LHS LED flashing RED and enters the user into the Illuminator Security Modes In...

Page 12: ...e pressed within 2 minutes the Illuminator times out and returns to the previous mode it was in either operating or programming mode 14 Manual Setting Level Indication using RHS Button The RHS BUTTON...

Page 13: ...Manual Button Control Solid RED Note If the illuminator is in Operating Mode and the buttons are currently disabled you cannot re enable 17 NOTE If no buttons are pressed within 2 minutes the illumin...

Page 14: ...sed in either Illuminator Settings Modes or Illuminator Configuration Modes the Illuminator will default into Operating Mode 30 minutes after the last button press RESET Options There are Two Re set o...

Page 15: ...and correctly wired 20 VARIO2 Specifications Table Infra Red Series White Light Series i16 w16 i8 w8 i6 i4 w4 i2 w2 10 500m 1640ft 250m 820ft 350m 1148ft 180m 591ft 200m 656ft 144m 472ft 110m 361ft 78...

Page 16: ...tion to ensure required distance is achievable Check unit is set to max power Check orientation of unit and ensure it is pointing in correct direction Check angle of unit Interchangeable lens Too narr...

Page 17: ...10 17 Raytec Global excluding Americas Tel 44 0 1670 520055 Fax 44 0 1670 819760 sales rayteccctv com Americas Tel 1 613 270 9990 Toll Free 1 888 505 8335 ussales rayteccctv com www rayteccctv com Ver...

Reviews: