21
VARIO2 Troubleshoot :
Ensure all tests are undertaken by a qualified, trained engineer. Ensure safe
working practices are followed at all times.
Step 1: Basics
•
Check polarity of illuminator connection red=+ve, black=-ve
•
Ensure power is 12-24V AC or DC (For Vario 16 variants : 24V AC or DC
only)
•
Ensure telemetry wires are shorted out or valid telemetry input (zero volt
or TTL) is applied and correctly wired
•
Check photocell is working. Cover photocell fully, light should turn on if
valid telemetry input. It is sometimes difficult to see Infra-Red illuminators
working in high brightness conditions.
•
Ensure power supply is suitably rated to product - check page 20 for
specifications
•
If longer cables used, ensure sufficient voltage is provided to allow for
drops across the cable
If OK…
Step 2: Illuminator Test
•
Check current is being drawn – amount of current will depend on
power setting of unit. Please note – use appropriate multimeter depending
on how the unit is being powered (AC or DC)
•
To test this you must ensure photocell fully covered (or disabled using
optional VARIO remote controller or manual control buttons) and ensure
telemetry wires are shorted out or valid telemetry input (zero volt or TTL) is
applied and correctly wired
20
VARIO2 Specifications Table :
Infra-Red Series & White-Light Series
i16
w16
i8
w8
i6
i4
w4
i2
w2
10°
500m
(1640ft)
250m
(820ft)
350m
(1148ft)
180m
(591ft)
200m
(656ft)
144m
(472ft)
110m
(361ft)
78m
(256ft)
60m
(197ft)
35°
250m
(820ft)
125m
(410ft)
165m
(541ft)
95m
(312ft)
120m
(394ft)
78m
(256ft)
65m
(213ft)
54m
(177ft)
40m
(131ft)
60°
135m
(443ft)
70m
(230ft)
95m
(311ft)
50m
(164ft)
70m
(230ft)
54m
(177ft)
35m
(115ft)
36m
(118ft)
25m
(82ft)
80°
105m
(344ft)
48m
(157ft)
70m
(230ft)
35m
(115ft)
50m
(164ft)
36m
(118ft)
25m
(82ft)
24m
(79ft)
20m
(66ft)
120°
65m
(213ft)
35m
(115ft)
45m
(148ft)
25m
(82ft)
30m
(98ft)
24m
(79ft)
18m
(59ft)
18m
(59ft)
12m
(39ft)
Consumption
100W
max
84W
max
46W
max
42W
max
25W
max
13W
max
24W
max
10W
max
11W
max
Input
24V AC/DC
12-24V AC/DC
12-24V AC/DC
12-24V AC/DC
Weight
3.1kg (6.8lbs)
1.65kg (3.61lbs)
950g (2.1lbs)
600g (1.3lbs)
Number of
LED’s
48
24
12
9
12
6
6
Environment
IP66
IP66
IP66
IP66
Dimensions
180 x 277 x 75mm
7”x11”x2.9”
135 x 180 x 68mm
(5”x7”x3”)
100 x 135 x 66m
4”x5”x2.5”)
75 x 100 x 64mm
3”x4”x2.5”)
Cable Length
2.5m
2.5m
2.5m
2.5m
2.5m
2.5m
2.5m
2.5m
2.5m
For 730nm, IR 940nm and other wavelengths, contact Raytec for distances
•
For i16; w16; i8; w8 the supply to the units should be limited to/ fused at 5A
•
For i6; w4 the supply to the units should be limited to/ fused at 3.15A
•
For i4; i2; w2 the supply to the units should be limited to/ fused at 1.6A
Standards:
CE (Covering EMC, Safety, IP rating)
FCC
IEC/EN 62471 (Photobiological Safety)