background image

11  

To delete an existing PIN you first need to be in Programming Mode by 

entering your PIN. Once in Programming Mode, press STATUS BUTTON for 

4 seconds to go into PIN set mode. LHS LED will flash RED / GREEN and 

RHS LED FLASHING  RED.  Instead of entering one of the known legal 

characters press the RESET BUTTON four times. The illuminator will return to 

programming mode. Note – if you delete the PIN and the illuminator 

times out into operating mode, you will not be able to go back to 

programming mode without recycling the power. 

*Note - If you forget your pin and need to make adjustments to the 

illuminator you need to do full Re-set. This  requires power  recycling whilst 

pressing the two manual control buttons at the same time. This will restore

factory default settings AND remove the previously programmed PIN. 

Both LEDs will flash AMBER to signify that the process has been 

completed. 

*Note – If you need to check if a PIN is set up,  in Operating Mode hold 

the status button down for 4 seconds and both LEDs flash RED, this means

there is no PIN present. 

10  

PIN Function Detail :

The PIN is set by using the Vario Remote Control (VRC). There are five 

buttons / characters on the remote that can be used for this purpose. 

They are Power 5, Power 1, Min Photocell (Smallest moon), Max Timer (Full 

Red Circle) & Timer Disable ( Timer Circle image with a line through) . 

Note – invalid characters will not be recognised. 

To create a PIN, press STATUS BUTTON for 4 seconds. LHS LED will flash  

RED/GREEN. This indication will always show that you are in PIN mode. 

RHS LED FLASHING RED shows there you are in PIN set mode. The number 

of flashes indicates how many characters are required to complete the 

PIN entry. There are four characters to be entered to successfully set up a 

PIN. 

As you enter the characters, the number of flashes will decrease until all 

characters are entered. Note, illegal characters will not be recognised 

and will not reduce the number of flashes. When the PIN is set the 

illuminator will revert to Programming Mode. 

When a PIN is Set : 
Using the remote you can access the illuminator settings from operating 

mode by entering the PIN. 
You cannot access Programming Mode by power re-cycling only.  

In operating mode, if you want to go back into programming mode 

simply enter your PIN. To do this, press STATUS BUTTON for 4 seconds. LHS 

LED will flash RED/GREEN to show you are in PIN mode. RHS LED FLASHING 

GREEN shows that a PIN has been previously set. As you input the four 

correct characters the number of flashes will reduce and you will be 

returned to programming mode. 

If legal characters but not the correct sequence of characters is entered 

the number of flashes will still reduce and after 4 characters have been 

entered an error will be shown by both LED`s flashing RED. 
If an illegal character is used when entering a pin, it will be ignored and 

the PIN character count will not reduce.  

Summary of Contents for VARIO2 VAR2-i2-2

Page 1: ...ed Photocell sensitivity MID Status LEDs ON No PIN Set Unit will change from Programming Mode to Operating Mode after 7 Days or 30 minutes after last press of manual buttons Timer Disabled VARIO2 Spec...

Page 2: ...plate at the bottom of the unit The number of button pushes indicated below are based on the user starting with the illuminator in either programming or operating mode Action Required Step1 LHS Button...

Page 3: ...two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are disabled The only remote control functions that can be used in Oper...

Page 4: ...rmittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down the No of characters required After PIN deleted Illuminator goes to Programming Mode Standard LED indication For full PIN...

Page 5: ...rking Cover photocell fully light should turn on if valid telemetry input It is sometimes difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably...

Page 6: ...eam and 120 beam angle ILS Bracketry VARIO2 Enhancements Increased Distance Default time for illuminator to go into Operating Mode reduced PIN function for enhanced security Manual Control added Push...

Page 7: ...mplete Set up and Installation Step 1 Select different beam angle if required To alter to 10 simply remove interchangeable lens ILS To alter to 60 replace with other ILS lens supplied Other angle ILS...

Page 8: ...control and buttons are available in Programming Mode The only function of the Remote Control available during Operating Mode is LED Status Indicators Enable Disable entering a PIN or disabling manua...

Page 9: ...ble manual buttons must be done within 5 minutes of remote disable 9 Extra VRC Functionality PIN Function For extra security VARIO2 allows a PIN Personal Identification Number to be set for each lamp...

Page 10: ...ough Note invalid characters will not be recognised To create a PIN press STATUS BUTTON for 4 seconds LHS LED will flash RED GREEN This indication will always show that you are in PIN mode RHS LED FLA...

Page 11: ...gs Power Level Photocell sensitivity Indicator LED status On or Off A continuous 4 second press of the LHS button turns LHS LED flashing RED and enters the user into the Illuminator Security Modes In...

Page 12: ...e pressed within 2 minutes the Illuminator times out and returns to the previous mode it was in either operating or programming mode 14 Manual Setting Level Indication using RHS Button The RHS BUTTON...

Page 13: ...Manual Button Control Solid RED Note If the illuminator is in Operating Mode and the buttons are currently disabled you cannot re enable 17 NOTE If no buttons are pressed within 2 minutes the illumin...

Page 14: ...sed in either Illuminator Settings Modes or Illuminator Configuration Modes the Illuminator will default into Operating Mode 30 minutes after the last button press RESET Options There are Two Re set o...

Page 15: ...and correctly wired 20 VARIO2 Specifications Table Infra Red Series White Light Series i16 w16 i8 w8 i6 i4 w4 i2 w2 10 500m 1640ft 250m 820ft 350m 1148ft 180m 591ft 200m 656ft 144m 472ft 110m 361ft 78...

Page 16: ...tion to ensure required distance is achievable Check unit is set to max power Check orientation of unit and ensure it is pointing in correct direction Check angle of unit Interchangeable lens Too narr...

Page 17: ...10 17 Raytec Global excluding Americas Tel 44 0 1670 520055 Fax 44 0 1670 819760 sales rayteccctv com Americas Tel 1 613 270 9990 Toll Free 1 888 505 8335 ussales rayteccctv com www rayteccctv com Ver...

Reviews: