In extreme sunlight conditions, distance between remote and unit may
need to be reduced
-
Programming may be disabled. Enter PIN to retrieve control or RESET
illuminator using one of the two RESET modes.
-
Battery failure. Check battery on remote (CR2025). Test 3 volt battery,
replace if necessary. Ensure battery has clean contacts.
-
Remote failure. Test with new remote
Step 4: Call Raytec for further assistance
Note down:
•
Model and serial number of illuminator
•
Camera make and model
•
Camera Lens make and model
If the Raytec illuminator or remote control is still not delivering the required
performance, please contact us for further assistance:
UK / Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
(Note : The light source (LEDs) of this Illuminator is not replaceable. When
the unit reaches its end of life the whole Illuminator shall be disposed of and
re-cycled where possible.)
Raytec Warranty
Please register your Raytec LED Illuminator(s) for its 5 year warranty by
visiting
www.rayteccctv.com/products/warranty-card
23
22
Step 3: Set up camera, lens, and illumination
•
Check model number to Raytec performance specification to ensure
required distance is achievable;
-
Check unit is set to max power
-
Check orientation of unit and ensure it is pointing in correct direction
-
Check angle of unit (Interchangeable lens) – Too narrow may cause
hot spots and the aperture of the camera lens to close down. Too wide
and there may be insufficient light on scene and light going where it is
not needed.
•
Check the LED status indicators for the status of the illuminator.
Programming mode – LHS Green Solid RHS LED flashes AMBER 1 sec on/off
Operating mode – LHS Green Solid
Status LEDs can be turned off in either mode – check if no LEDs visible.
LHS SOLID GREEN:
Power Applied
LHS FLASHING GREEN: Remote control IR receiver problem
RHS FLASHING AMBER: Indicates unit is in programming mode
RHS SOLID AMBER:
Indicates that a valid command is being received
LHS FLASHING RED:
Voltage supply problem detected
LHS SOLID RED:
Illuminator fault detected
Note: the if there is a voltage supply error, the LHS RED LED will FLASH RED
but extinguish and revert to the standard SOLD GREEN when the correct
voltage has been restored.
The fault indications are non latching
•
Check unit is responding to remote /Manual Control buttons.
If not..
-
Status indicators may be turned off. Turn on with remote or with manual
buttons. This can be done even if programming has been disabled