background image

Wiring:

1. Mount Illuminator
2. Connect Illuminator to low voltage input 12-24V AC/DC

IMPORTANT: For Vario 16 variants : 24V only AC/DC

3. Complete configuration, wiring and final set-up using manual push buttons on

the illuminator or VARIO Remote Controller (VRC) - VRC is  an optional

  accessory 

Black Wire = Negative (-ve) 
Red Wire = Positive (+ve) 
White & Yellow wires = Photocell following contact, Volt free output, Non polarity 
sensitive 
Orange and Purple Wires = Telemetry input Volt free / dry contact or TTL input 

Lens Selection: 

VARIO is factory set and delivered with a 35˚ beam width angle.

 

To alter to 10˚, simply remove interchangeable lens (ILS).  

To alter to 60˚, replace with other ILS lens supplied. 

Other angle ILS lenses are available to order: 80˚ and 120˚. 

Please handle ILS lenses with care – and do not touch optical film. 

Use 2.5mm Allen/hex key. Re-attach base plate securely ensuring gasket is 

correctly located. 

(Screw Torque: 0.6Nm)

 

Important Note : Ensure base plate is securely located, the gasket is 
correctly located and the screws correctly fastened to ensure and 
maintain IP66 rating of the product 

Manual Button Operation 

Buttons are accessed by removing the base plate at the bottom of the unit.  
The number of button pushes indicated below are based on the user starting 
with the illuminator in either programming or operating mode.

Action 

Required 

Step1 :  

LHS Button 

LHS 

 LED 

Step 2 : 

 RHS Button 

RHS 

 LED 

Comment 

Power Adjust  1 x Push 

Solid 

Red 

Each Push 

cycles 

through 

power 

levels 

Green flashes 

indicate  level. 

High power (5 

flashes) to Low 

power (1 flash) 

Photocell 

Adjust 

2 x Push 

Solid 

Green 

Each Push 

cycles 

through 

photocell 

levels 

Green flashes 

indicate  3 

sensitivity 

settings: 

Low:  1 Flash 

Med: 2 Flashes 

High: 3 Flashes 

Solid Red for 

Photocell 

disabled. 

Status 

Indicator 

LEDS On / Off 

3 x Push 

Solid 

Amber 

Each Push 

cycles 

between 

On and 

Off 

On – Green 

Off - Red 

Factory Re-

set (Does not 

Re-set PIN) 

1 x Long 

Push 

(4 

Seconds) 

Flashing 

Red – 

Push and 

Hold until 

both LEDs 

flash 

Amber 

Solid Red – After 

4s both LEDs 

Flashing Amber 

Reverts to 

Programming 

Mode unless a 

PIN is present. If a 

PIN is present 

reverts to original 

mode before re-

set 

Disable 

Remote 

Control

 

Change 

between 

Programming 

Mode and 

Operating 
Mode

 

1 x Long 

Push (4s),  

then 1 x 

short Push 

Flashing 

Green 

Push to 

cycle 

Disable / 

Enable 

Disable – Red 

Enable - Green 

Reverts to the

 

Mode requested

 

unless a PIN is

 

present. If a PIN 

is 

present and you

 

are in Operating

 

Mode you

 cannot

 

change

 

to pro-

Disable remote 

(enter OP Mode) 

or Enable remote 
(enter prog. Mode)

 

gramming Mode.

Summary of Contents for VARIO2 VAR2-i2-2

Page 1: ...ed Photocell sensitivity MID Status LEDs ON No PIN Set Unit will change from Programming Mode to Operating Mode after 7 Days or 30 minutes after last press of manual buttons Timer Disabled VARIO2 Spec...

Page 2: ...plate at the bottom of the unit The number of button pushes indicated below are based on the user starting with the illuminator in either programming or operating mode Action Required Step1 LHS Button...

Page 3: ...two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are disabled The only remote control functions that can be used in Oper...

Page 4: ...rmittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down the No of characters required After PIN deleted Illuminator goes to Programming Mode Standard LED indication For full PIN...

Page 5: ...rking Cover photocell fully light should turn on if valid telemetry input It is sometimes difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably...

Page 6: ...eam and 120 beam angle ILS Bracketry VARIO2 Enhancements Increased Distance Default time for illuminator to go into Operating Mode reduced PIN function for enhanced security Manual Control added Push...

Page 7: ...mplete Set up and Installation Step 1 Select different beam angle if required To alter to 10 simply remove interchangeable lens ILS To alter to 60 replace with other ILS lens supplied Other angle ILS...

Page 8: ...control and buttons are available in Programming Mode The only function of the Remote Control available during Operating Mode is LED Status Indicators Enable Disable entering a PIN or disabling manua...

Page 9: ...ble manual buttons must be done within 5 minutes of remote disable 9 Extra VRC Functionality PIN Function For extra security VARIO2 allows a PIN Personal Identification Number to be set for each lamp...

Page 10: ...ough Note invalid characters will not be recognised To create a PIN press STATUS BUTTON for 4 seconds LHS LED will flash RED GREEN This indication will always show that you are in PIN mode RHS LED FLA...

Page 11: ...gs Power Level Photocell sensitivity Indicator LED status On or Off A continuous 4 second press of the LHS button turns LHS LED flashing RED and enters the user into the Illuminator Security Modes In...

Page 12: ...e pressed within 2 minutes the Illuminator times out and returns to the previous mode it was in either operating or programming mode 14 Manual Setting Level Indication using RHS Button The RHS BUTTON...

Page 13: ...Manual Button Control Solid RED Note If the illuminator is in Operating Mode and the buttons are currently disabled you cannot re enable 17 NOTE If no buttons are pressed within 2 minutes the illumin...

Page 14: ...sed in either Illuminator Settings Modes or Illuminator Configuration Modes the Illuminator will default into Operating Mode 30 minutes after the last button press RESET Options There are Two Re set o...

Page 15: ...and correctly wired 20 VARIO2 Specifications Table Infra Red Series White Light Series i16 w16 i8 w8 i6 i4 w4 i2 w2 10 500m 1640ft 250m 820ft 350m 1148ft 180m 591ft 200m 656ft 144m 472ft 110m 361ft 78...

Page 16: ...tion to ensure required distance is achievable Check unit is set to max power Check orientation of unit and ensure it is pointing in correct direction Check angle of unit Interchangeable lens Too narr...

Page 17: ...10 17 Raytec Global excluding Americas Tel 44 0 1670 520055 Fax 44 0 1670 819760 sales rayteccctv com Americas Tel 1 613 270 9990 Toll Free 1 888 505 8335 ussales rayteccctv com www rayteccctv com Ver...

Reviews: