background image

Action 

Required 

     Step1 :  

LHS Button 

    LHS 

LED 

   Step 2 : 

RHS Button 

      RHS 

LED 

Comment 

Disable / 

Enable 

Manual 

Buttons 

1 x Long 

Push (4s), 

then 2 x 

short Push 

Flashing 

Amber 

Push to 

cycle 

Disable / 

Enable 

Disable – Red 

Enable - Green 

Buttons will be 

Disabled 30 

minutes after this 

selection is made 

– This is to allow

the user to re-

enable manual

buttons if

required

Full Re-set 

(including 

PIN re-set) 

Keep both 

buttons 

depressed 

during 

power up – 

LEDs will 

both flash 

Amber 

Flashing 

Amber 

then 
solid 
green 
after 
button 
release 

Keep both 

buttons 

depressed 

during 

power up 

– LEDs will

both flash

Amber

Flashing Amber 

then Flashing 

Amber after 

button release 

Illuminator  will 

revert to 

Programming 

Mode, Full 

factory default 

including No PIN 

The illuminator has two modes; 

(1)

Programming Mode when the remote control can be used and

(2)

Operating Mode when most of the remote control functions are disabled.

The only remote control functions that can be used in Operating mode are;
Enable/Disable Status LEDs, Disable Manual Buttons and PIN entry.

Manual Buttons are always available in programming mode or if they have been 
disabled, they can be enabled in programming mode. 

Manual Buttons are available in operating mode, provided they have not already 
been disabled.   

The number of button pushes indicated above are based on the user starting with 
the illuminator in either programming or operating mode. 

If no buttons are pressed within 2 minutes then the illuminator will automatically 
default back into the previous mode it was in – programming or operating mode. 

Press again for 4 seconds to 

disable manual buttons – 

must be done within 5 

minutes of remote disable 

This will NOT remove 

PIN if present 

Summary of Contents for VARIO2 VAR2-i2-1

Page 1: ...ed Photocell sensitivity MID Status LEDs ON No PIN Set Unit will change from Programming Mode to Operating Mode after 7 Days or 30 minutes after last press of manual buttons Timer Disabled VARIO2 Spec...

Page 2: ...plate at the bottom of the unit The number of button pushes indicated below are based on the user starting with the illuminator in either programming or operating mode Action Required Step1 LHS Button...

Page 3: ...two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are disabled The only remote control functions that can be used in Oper...

Page 4: ...rmittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down the No of characters required After PIN deleted Illuminator goes to Programming Mode Standard LED indication For full PIN...

Page 5: ...rking Cover photocell fully light should turn on if valid telemetry input It is sometimes difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably...

Page 6: ...eam and 120 beam angle ILS Bracketry VARIO2 Enhancements Increased Distance Default time for illuminator to go into Operating Mode reduced PIN function for enhanced security Manual Control added Push...

Page 7: ...mplete Set up and Installation Step 1 Select different beam angle if required To alter to 10 simply remove interchangeable lens ILS To alter to 60 replace with other ILS lens supplied Other angle ILS...

Page 8: ...control and buttons are available in Programming Mode The only function of the Remote Control available during Operating Mode is LED Status Indicators Enable Disable entering a PIN or disabling manua...

Page 9: ...ble manual buttons must be done within 5 minutes of remote disable 9 Extra VRC Functionality PIN Function For extra security VARIO2 allows a PIN Personal Identification Number to be set for each lamp...

Page 10: ...ough Note invalid characters will not be recognised To create a PIN press STATUS BUTTON for 4 seconds LHS LED will flash RED GREEN This indication will always show that you are in PIN mode RHS LED FLA...

Page 11: ...gs Power Level Photocell sensitivity Indicator LED status On or Off A continuous 4 second press of the LHS button turns LHS LED flashing RED and enters the user into the Illuminator Security Modes In...

Page 12: ...e pressed within 2 minutes the Illuminator times out and returns to the previous mode it was in either operating or programming mode 14 Manual Setting Level Indication using RHS Button The RHS BUTTON...

Page 13: ...Manual Button Control Solid RED Note If the illuminator is in Operating Mode and the buttons are currently disabled you cannot re enable 17 NOTE If no buttons are pressed within 2 minutes the illumin...

Page 14: ...sed in either Illuminator Settings Modes or Illuminator Configuration Modes the Illuminator will default into Operating Mode 30 minutes after the last button press RESET Options There are Two Re set o...

Page 15: ...and correctly wired 20 VARIO2 Specifications Table Infra Red Series White Light Series i16 w16 i8 w8 i6 i4 w4 i2 w2 10 500m 1640ft 250m 820ft 350m 1148ft 180m 591ft 200m 656ft 144m 472ft 110m 361ft 78...

Page 16: ...tion to ensure required distance is achievable Check unit is set to max power Check orientation of unit and ensure it is pointing in correct direction Check angle of unit Interchangeable lens Too narr...

Page 17: ...10 17 Raytec Global excluding Americas Tel 44 0 1670 520055 Fax 44 0 1670 819760 sales rayteccctv com Americas Tel 1 613 270 9990 Toll Free 1 888 505 8335 ussales rayteccctv com www rayteccctv com Ver...

Reviews: