Installation Steps:
1
.
VARIO2 is factory set and delivered with a 35˚
beam width.
To alter to 10˚, simply remove interchangeable
lens (ILS). See page 4 for detailed instructions
To alter to 60˚, replace with other ILS lens
supplied.
2. Mount Illuminator
3. Connect Illuminator to low voltage input 12-24V
AC/DC (For Vario 16 variants : 24V AC or DC only)
4-6. Complete configuration, wiring and final set-up using manual push
buttons on the illuminator or VARIO Remote Controller (VRC)
- VRC is an optional accessory
The external cable cannot be replaced. If it is damaged and the customer
is unable to shorten and re-use the cable, the illuminator must not be
powered.
Wiring – six core cable
White & Yellow wires =
Photocell following contact,
Volt free output, Non polarity sensitive
Orange and Purple Wires =
Telemetry input Volt free / dry contact or
TTL input (see Page 5 and 6 for more detail)
DC
AC
Black Wire -
~
Red Wire
+
~
Photocell
Cable
Breather
Gland
2
Box Contents :
VARIO2 Illuminator , spare 60° beam angles ILS
(ILS: Interchangeable Lens System)
Accessories (Optional) :VARIO Remote Control for additional Programming;
80˚ beam and 120˚ beam angle ILS; Bracketry
VARIO2 Enhancements
•
Increased Distance
•
Default time for illuminator to go into Operating Mode reduced
•
PIN function for enhanced security
•
Manual Control added – Push Buttons Accessible on the illuminator
•
Improved RESET Options
•
The 3 single colour feedback LED’s have been replaced with
2 tri-colour LED’s
Safety Information
Eye Safety : IR Variants (850nm and 940nm)
Caution – IR emitted from this product EN62471 Risk Group 2
Do not stare at the lamp. Avoid exposure or use appropriate
shielding / eye protection. Risk Group 2 for cornea / lens
infrared hazard. For VAR-i2, VAR-i4, VAR-i6 and VAR-i8
variants hazard distance is 1500mm. For VAR-i16 hazard
distance is 1840mm. Max IR EHV (Exposure Hazard Value) :
69% of Risk Group 2 Limit at 200mm from the lamp.
Eye Safety : White Light and 730nm variants
Caution – EN62471 Risk Group 2 Classification - Possible
hazardous optical radiation emitted from this product. May
be harmful to eyes, do not stare at the lamp. For VAR-w2,
VAR-w4, VAR-w8 Hazard distance is 1500mm. For VAR-w16
hazard distance is 1840mm. Max WL EHV (Exposure Hazard
Value) : 68% of Risk Group 2 Limit at 200mm from the lamp.
Eye Safety: Other Wavelengths - Contact Raytec.
The Illuminator is Class lll for insulation