background image

-

In extreme sunlight conditions, distance between remote and unit may
need to be reduced

-

Programming may be disabled. Enter PIN to retrieve control or RESET
illuminator using one of the two RESET modes.

-

Battery failure. Check battery on remote (CR2025). Test 3 volt battery,
replace if necessary. Ensure battery has clean contacts.

-

Remote failure. Test with new remote

Step 4: Call Raytec for further assistance 
Note down: 

Model and serial number of illuminator

Camera make and model

Camera Lens make and model

If the Raytec illuminator or remote control is still not delivering the required
performance, please contact us for further assistance:
UK / Europe Tel: +44 (0) 1670 520055 
Americas Tel: +1 613 270 9990 

(Note : The light source (LEDs) of this Illuminator is not replaceable. When  
the unit  reaches its end of life the whole Illuminator shall be disposed of and 
re-cycled where possible.) 

Raytec Warranty 
Please register your  Raytec LED Illuminator(s) for its 5 year warranty by 
visiting 

www.rayteccctv.com/products/warranty-card 

23  

22  

Step 3: Set up camera, lens, and illumination 

Check model number to Raytec performance specification to ensure
required distance is achievable;

-

Check unit is set to max power

-

Check orientation of unit and ensure it is pointing in correct direction

-

Check angle of unit (Interchangeable  lens) – Too narrow may cause
hot spots and the aperture of the camera lens to close down. Too wide
and there may be insufficient light on scene and light going where it is
not needed.

Check the LED status indicators for the status of the illuminator.

Programming mode –  LHS Green Solid RHS LED flashes AMBER 1 sec on/off 
Operating mode – LHS Green Solid 
Status LEDs can be turned off in either mode – check if no LEDs visible. 

LHS SOLID GREEN: 

Power Applied 

LHS FLASHING GREEN:  Remote control IR receiver problem 
RHS FLASHING AMBER:  Indicates unit is in programming mode 
RHS SOLID AMBER: 

Indicates that a valid command is being received 

LHS FLASHING RED: 

Voltage supply problem detected 

LHS SOLID RED:  

Illuminator fault detected 

Note: the if there is a voltage supply error, the LHS RED LED will FLASH RED 
but extinguish and revert to the standard SOLD GREEN when the correct 
voltage has been restored. 

The fault indications are non latching 

Check unit is responding to remote /Manual Control buttons.

If not..
-

Status indicators may be turned off. Turn on with remote or with manual
buttons. This can be done even if programming has been disabled

Summary of Contents for VARIO2 VAR2-i2-1

Page 1: ...ed Photocell sensitivity MID Status LEDs ON No PIN Set Unit will change from Programming Mode to Operating Mode after 7 Days or 30 minutes after last press of manual buttons Timer Disabled VARIO2 Spec...

Page 2: ...plate at the bottom of the unit The number of button pushes indicated below are based on the user starting with the illuminator in either programming or operating mode Action Required Step1 LHS Button...

Page 3: ...two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are disabled The only remote control functions that can be used in Oper...

Page 4: ...rmittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down the No of characters required After PIN deleted Illuminator goes to Programming Mode Standard LED indication For full PIN...

Page 5: ...rking Cover photocell fully light should turn on if valid telemetry input It is sometimes difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably...

Page 6: ...eam and 120 beam angle ILS Bracketry VARIO2 Enhancements Increased Distance Default time for illuminator to go into Operating Mode reduced PIN function for enhanced security Manual Control added Push...

Page 7: ...mplete Set up and Installation Step 1 Select different beam angle if required To alter to 10 simply remove interchangeable lens ILS To alter to 60 replace with other ILS lens supplied Other angle ILS...

Page 8: ...control and buttons are available in Programming Mode The only function of the Remote Control available during Operating Mode is LED Status Indicators Enable Disable entering a PIN or disabling manua...

Page 9: ...ble manual buttons must be done within 5 minutes of remote disable 9 Extra VRC Functionality PIN Function For extra security VARIO2 allows a PIN Personal Identification Number to be set for each lamp...

Page 10: ...ough Note invalid characters will not be recognised To create a PIN press STATUS BUTTON for 4 seconds LHS LED will flash RED GREEN This indication will always show that you are in PIN mode RHS LED FLA...

Page 11: ...gs Power Level Photocell sensitivity Indicator LED status On or Off A continuous 4 second press of the LHS button turns LHS LED flashing RED and enters the user into the Illuminator Security Modes In...

Page 12: ...e pressed within 2 minutes the Illuminator times out and returns to the previous mode it was in either operating or programming mode 14 Manual Setting Level Indication using RHS Button The RHS BUTTON...

Page 13: ...Manual Button Control Solid RED Note If the illuminator is in Operating Mode and the buttons are currently disabled you cannot re enable 17 NOTE If no buttons are pressed within 2 minutes the illumin...

Page 14: ...sed in either Illuminator Settings Modes or Illuminator Configuration Modes the Illuminator will default into Operating Mode 30 minutes after the last button press RESET Options There are Two Re set o...

Page 15: ...and correctly wired 20 VARIO2 Specifications Table Infra Red Series White Light Series i16 w16 i8 w8 i6 i4 w4 i2 w2 10 500m 1640ft 250m 820ft 350m 1148ft 180m 591ft 200m 656ft 144m 472ft 110m 361ft 78...

Page 16: ...tion to ensure required distance is achievable Check unit is set to max power Check orientation of unit and ensure it is pointing in correct direction Check angle of unit Interchangeable lens Too narr...

Page 17: ...10 17 Raytec Global excluding Americas Tel 44 0 1670 520055 Fax 44 0 1670 819760 sales rayteccctv com Americas Tel 1 613 270 9990 Toll Free 1 888 505 8335 ussales rayteccctv com www rayteccctv com Ver...

Reviews: