background image

RESET: 

Settings Re-set : Pressing and holding the RESET BUTTON on the remote control 

or using the manual buttons to complete a RESET will restore the factory 

settings to the illuminator. Note : It will not remove a PIN if one is present. 

Full Re-set : Re-cycling the power whilst pressing both manual buttons will 

restore factory settings and remove a PIN if one is present. 

Both indicator LEDs flash amber for both above re-sets when complete. 

VARIO2 Quick Troubleshoot: 

Ensure all tests are undertaken by a qualified, trained engineer. Ensure safe 

working practices are followed at all times. 

Check polarity of illuminator connection red=+ve, black=-ve

Ensure power is 12-24V AC or DC (For Vario 16 variants : 24V only AC or DC )

Ensure telemetry wires are shorted out or valid telemetry input (zero volt or

TTL) is applied and correctly wired

Check photocell is working. Cover photocell fully, light should turn on if valid

telemetry input. It is sometimes difficult to see Infra-Red illuminators working in high

brightness conditions.

Ensure power supply is suitably rated to product - check page 1 for

specifications

If longer cables used, ensure sufficient voltage is provided to allow for drops

across the cable

For in-depth Troubleshoot, see Full Instructions, or contact Raytec. 

FFu

ullll  IIn

nsstta

alllla

attiio

on

n  G

Gu

uiid

de

e  

Contents : 

Page 2 

Box Contents and Safety Information 

Page 3 

Short Guide and Factory Defaults 

Page 6 

LED Status Indicators – Feedback System 

Page 8 

VARIO Remote Controller (VRC) 

Page 10 

PIN Function Detail 

Page 12 

Manual Control Buttons  

Page 17 

Disabling Manual Buttons  

Page 18 

Power Up Functionality ; Re-Set Options 

Page 19 

Standard Bracketry 

Page 20 

Specifications Table 

Page 21 

Troubleshooting

VV

ee

rr.. 

 11

00//

117

9

UK / Europe
Tel: +44 (0) 1670 520055
[email protected]

Americas   
Tel:  +1 613 270 9990
Toll Free: +1 888 505 8335 
[email protected]

www.rayteccctv.com

Summary of Contents for VARIO2 VAR2-i2-1

Page 1: ...ed Photocell sensitivity MID Status LEDs ON No PIN Set Unit will change from Programming Mode to Operating Mode after 7 Days or 30 minutes after last press of manual buttons Timer Disabled VARIO2 Spec...

Page 2: ...plate at the bottom of the unit The number of button pushes indicated below are based on the user starting with the illuminator in either programming or operating mode Action Required Step1 LHS Button...

Page 3: ...two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are disabled The only remote control functions that can be used in Oper...

Page 4: ...rmittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down the No of characters required After PIN deleted Illuminator goes to Programming Mode Standard LED indication For full PIN...

Page 5: ...rking Cover photocell fully light should turn on if valid telemetry input It is sometimes difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably...

Page 6: ...eam and 120 beam angle ILS Bracketry VARIO2 Enhancements Increased Distance Default time for illuminator to go into Operating Mode reduced PIN function for enhanced security Manual Control added Push...

Page 7: ...mplete Set up and Installation Step 1 Select different beam angle if required To alter to 10 simply remove interchangeable lens ILS To alter to 60 replace with other ILS lens supplied Other angle ILS...

Page 8: ...control and buttons are available in Programming Mode The only function of the Remote Control available during Operating Mode is LED Status Indicators Enable Disable entering a PIN or disabling manua...

Page 9: ...ble manual buttons must be done within 5 minutes of remote disable 9 Extra VRC Functionality PIN Function For extra security VARIO2 allows a PIN Personal Identification Number to be set for each lamp...

Page 10: ...ough Note invalid characters will not be recognised To create a PIN press STATUS BUTTON for 4 seconds LHS LED will flash RED GREEN This indication will always show that you are in PIN mode RHS LED FLA...

Page 11: ...gs Power Level Photocell sensitivity Indicator LED status On or Off A continuous 4 second press of the LHS button turns LHS LED flashing RED and enters the user into the Illuminator Security Modes In...

Page 12: ...e pressed within 2 minutes the Illuminator times out and returns to the previous mode it was in either operating or programming mode 14 Manual Setting Level Indication using RHS Button The RHS BUTTON...

Page 13: ...Manual Button Control Solid RED Note If the illuminator is in Operating Mode and the buttons are currently disabled you cannot re enable 17 NOTE If no buttons are pressed within 2 minutes the illumin...

Page 14: ...sed in either Illuminator Settings Modes or Illuminator Configuration Modes the Illuminator will default into Operating Mode 30 minutes after the last button press RESET Options There are Two Re set o...

Page 15: ...and correctly wired 20 VARIO2 Specifications Table Infra Red Series White Light Series i16 w16 i8 w8 i6 i4 w4 i2 w2 10 500m 1640ft 250m 820ft 350m 1148ft 180m 591ft 200m 656ft 144m 472ft 110m 361ft 78...

Page 16: ...tion to ensure required distance is achievable Check unit is set to max power Check orientation of unit and ensure it is pointing in correct direction Check angle of unit Interchangeable lens Too narr...

Page 17: ...10 17 Raytec Global excluding Americas Tel 44 0 1670 520055 Fax 44 0 1670 819760 sales rayteccctv com Americas Tel 1 613 270 9990 Toll Free 1 888 505 8335 ussales rayteccctv com www rayteccctv com Ver...

Reviews: