background image

6

X

tremely Easy to Wire

300

28

17

19

8

14

5

14

5

40

36

28

16

400

38

18

25

7

19

4

19

4

40

47

29

16

500

47

16

31

7

24

4

24

4

40

56

23

17

700

66

30

44

13

33

7

33

7

40

70

34

19

850

80

40

53

17

40

9

40

9

40

80

40

20

XFyre

Model

20°F

GPM

D

T

40°F

30°F

Minimum Flow*

Rates Of Flow And Pressure Drops

300

1711

1140

855

684

570

489

428

380

342

400

2275

1517

1138

910

758

650

569

506

455

500

2851

1901

1426

1140

950

815

713

634

570

700

3992

2661

1996

1597

1331

1140

998

887

798

850

4847

3231

2423

1939

1616

1385

1212

1077

969

Temperature Rise (°F)

XFyre

Model 

100

80

90

60

70

40

50

30

20

Recovery Rates

300

30

19

8

1.5

10

24

24

17

1.5

19

400

30

25

7

2

8

20

38

18

2

21

500

30

31

7

2

8

20

47

16

2

20

700

30

44

13

2

17

20

66

30

2

38

850

32

51

16

2

20

24

67

28

2

36

Soft 

(0-4 Grains Per Gallon)

Water Hardness

Hard 

(16-25 Grains Per Gallon)

Medium 

(5-15 Grains Per Gallon)

XFyre

Model

Maximum Flow

GPM

D

T

*Closed systems only

D

P

D

P

GPM

D

P

GPM

D

P

GPM

D

P

D

T

D

P

MTS

D

T

GPM

SHL

GPM

MTS

D

P

SHL

Do not use when hardness

exceeds 15 grains per gallon

MTS = Minimum Tube Size, inch.
SHL = System Head Loss, ft (based on heater and tank placed no more than 5 ft apart).

D

T = Temperature rise, °F

D

P = Pressure drop through heat exchanger, ft

Hydronic Boiler

Water Heater

D

T GPM

MTS

D

P

SHL

120VAC Wiring Center

The XFyre’s 120VAC wiring center is located on the rear
of the boiler. All incoming line voltage and pump wiring
are contained away from the 24v control wiring. Wiring
the boiler is simple and straight forward.

Low Voltage Wiring Center

Just like its big brother the XTherm, the XFyre has a
separate front mounted wiring center for all of the
low voltage connections. This makes thermostat, water
sensor, 0-10VDC BMS, and alarm contacts a breeze to
set up. No more guessing where the contact points
are buried in the boiler. Built-in cascade control using
CAT 3 or CAT 5 computer network patch cables to
connect with the communication bus between boilers.
Simply remove the front door for quick access.

120VAC Wiring Center

(rear of boiler)

Low Voltage

Wiring Center

Summary of Contents for XFYRE 500

Page 1: ...up to 99 Efficiency Can be vented with PVC MBTU Models 300 400 500 700 850 CSA Verified lead Content Less Than 25 Pb Ultra Low Emissions...

Page 2: ...n ensures efficiency is maintained throughout the firing rate and actually increases during part load right when you want it The XFyre automatically self tunes to accommodate the widest range of gas s...

Page 3: ...h flexibility XFyre is the right boiler for almost any size job 6 Intake Air Filter Every XFyre comes standard with a front access removable Merv 8 media combustion air filter 7 Manual Reset High Limi...

Page 4: ...iler Control Raypak uses German made high quality Dungs gas valves considered the finest modulating gas valves produced today To the right of the gas valve is the boiler computer control center which...

Page 5: ...Input Minimum Input 300 300 282 94 300 285 95 60 400 399 375 94 399 379 95 80 500 500 470 94 500 475 95 100 700 700 658 94 700 665 95 140 850 850 799 94 850 808 95 170 Model Dimensions in A Length Am...

Page 6: ...GPM DP GPM DP GPM DP DT DP MTS DT GPM SHL GPM MTS DP SHL Do not use when hardness exceeds 15 grains per gallon MTS Minimum Tube Size inch SHL System Head Loss ft based on heater and tank placed no mo...

Page 7: ...tdoor Sensor Line Voltage Blocked Vent Low Water Level 24 Volt Low Low Water Flow Temper Blocking High Temperature Flue Gas Pressure Supply Thermistor Return Thermistor Supply High Ignition Control Fa...

Page 8: ...r Reset Sensor N A V Multiple Boiler Controller TempTracker Mod Hybrid up to 16 boilers groups V V Direct Spark Ignition System 1 try V V 4 try v v High Low Gas Pressure Switches V V Blocked Vent Swit...

Reviews: