background image

ASME Section IV, National Board Registered, 160 PSI • H Stamp

v

v

Heat Exchanger Tubes

• 316L Stainless Steel

v

v

Stainless Steel

• CSA Verified AB-1953 CA low lead compliant

v

v

Pressure Relief Valve

• 60 PSI

V

v

(loose)

• 125 PSI

v

V

• 30, 45, 75, 150 PSI

V

V

Temperature & Pressure Gauge (Loose)

v

v

Pump

• 120V, Single-Phase

V

V

Indoor/Outdoor Certified

v

v

Vent Terminal

• Outdoor

V

V

• Through-the-Wall

V

V

Fully-Enclosed Controls

v

v

Combustible Floor Rated

v

v

120V Power Supply 

v

v

On/Off Switch

v

v

Programmable Pump Time Delay, Single-Phase

• Included in Controller

v

v

Terminal Block Connections

• Enable / Disable

v

v

(Front mounted)

• 0-10 VDC Setpoint/Direct Drive Input

v

v

LCD diagnostic display with 10-Event History (2x20 character display, reads in plain English)

v

v

Temperature Controller with 3 Water Sensors

• (up to 5:1 Turndown)

v

v

• Outdoor Reset Sensor

N/A

V

Multiple Boiler Controller

• TempTracker Mod+ Hybrid, up to 16 boilers/groups

V

V

Direct Spark Ignition System

• 1-try

V

V

• 4-try

v

v

High/Low Gas Pressure Switches

V

V

Blocked Vent Switch

v

v

High Limit Switch

• Manual Reset, Fixed

v

v

• Automatic Reset, Fixed

V

V

Low Water Cut-Off, 24V

• With Manual Reset and Test Buttons

V

V

Flow Switch

v

v

Modulating Combination Gas Valve

v

v

Combustion Air Blower

v

v

Additional Safety Valve

• Motorized (externally mounted)

V

V

• Solenoid (externally mounted)

V

V

CSA-Certified Efficiency

• 94% at Full Fire

N/A

v

• 95% at Full Fire

v

N/A

• 99% at Part Load

v

v

Air Filter

v

v

TruSeal Direct-Vent

V

V

Alarm Contacts

v

v

CSD-1 / GE GAP Control System

V

V

Low NOx

• Meets all current requirements

v

v

Condensate Drain and Trap

v

v

Condensate Neutralizer

V

V

Water 

Heaters

(Type WH)

Boilers

(Type H)

v

v

= Standard       

V

V

= Optional

Raypak, Inc.

•  2151 Eastman Avenue, Oxnard, CA 93030 • phone: (805) 278-5300 • fax: (800) 872-8725 • www.raypak.com

© 2009-2010 Raypak, Inc.

Cat. No. 1000.22B    Effective: 07-15-10    Replaces: 02-15-10 

Summary of Contents for XFYRE 500

Page 1: ...up to 99 Efficiency Can be vented with PVC MBTU Models 300 400 500 700 850 CSA Verified lead Content Less Than 25 Pb Ultra Low Emissions...

Page 2: ...n ensures efficiency is maintained throughout the firing rate and actually increases during part load right when you want it The XFyre automatically self tunes to accommodate the widest range of gas s...

Page 3: ...h flexibility XFyre is the right boiler for almost any size job 6 Intake Air Filter Every XFyre comes standard with a front access removable Merv 8 media combustion air filter 7 Manual Reset High Limi...

Page 4: ...iler Control Raypak uses German made high quality Dungs gas valves considered the finest modulating gas valves produced today To the right of the gas valve is the boiler computer control center which...

Page 5: ...Input Minimum Input 300 300 282 94 300 285 95 60 400 399 375 94 399 379 95 80 500 500 470 94 500 475 95 100 700 700 658 94 700 665 95 140 850 850 799 94 850 808 95 170 Model Dimensions in A Length Am...

Page 6: ...GPM DP GPM DP GPM DP DT DP MTS DT GPM SHL GPM MTS DP SHL Do not use when hardness exceeds 15 grains per gallon MTS Minimum Tube Size inch SHL System Head Loss ft based on heater and tank placed no mo...

Page 7: ...tdoor Sensor Line Voltage Blocked Vent Low Water Level 24 Volt Low Low Water Flow Temper Blocking High Temperature Flue Gas Pressure Supply Thermistor Return Thermistor Supply High Ignition Control Fa...

Page 8: ...r Reset Sensor N A V Multiple Boiler Controller TempTracker Mod Hybrid up to 16 boilers groups V V Direct Spark Ignition System 1 try V V 4 try v v High Low Gas Pressure Switches V V Blocked Vent Swit...

Reviews: