Ratings shown are for elevations up to 10,000 feet. For installations at elevations above
2,000 feet, derate may apply, please consult the factory for additional instructions.

Front

24”

24”

Rear

24”

24”

Right 

0”

0”

Left 

0”

0”

Top

12”

24”

Floor

0”

---

Vent

1”

---

C e r t i f i e d

M i n i m u m

Service

Minimum

*Do not install on carpeting
Note: Local codes may require increased clearances

Heater

Side

Note: Current draw (Amps) is for pump only

Water hardness grains per gallon
Soft = 0-4 • Medium = 5-15 • Hard = 16-25

Water above 15gpg requires water softener.

Model MBTUH

Input

Boiler

Output

Efficiency

Water Heaters

Output

Efficiency

MBTUH

Input

Minimum

Input

300

300

282

94%

300

285

95%

60

400

399

375

94%

399

379

95%

80

500

500

470

94%

500

475

95%

100

700

700

658

94%

700

665

95%

140

850

850

799

94%

850

808

95%

170

Model

Dimensions (in.)

A

Length

Amps*

3 0 0

28 - 1/4

16 - 1/2

27 - 9/16

3 / 4

1 - 1/2

4

4

3

4 1 0

4 . 3

3

4 0 0

30 - 3/4

16 - 1/2

29 - 3/4

1

2

4

4

3

4 6 5

4 . 7

4

5 0 0

37 - 1/4

16 - 1/2

36 - 1/4

1

2

4

4

3

5 0 5

5 . 7

4

7 0 0

47 - 3/4

2 8

47 - 1/16

1 - 1/4

2

6

6

19 - 3/8

5 5 0

7 . 3

5

8 5 0

54 - 1/4

2 8

53 - 9/16

1 - 1/4

2

6

6

19 - 3/8

5 8 0

8 . 3

5

Foot-

Print

(ft

2

)

Ship

Weight

(lbs.)

E

F

Mounting

G

NPT

H

NPT

K

Flue Ø

T

C/A 

Ø

V

300

1/8

1.3

1/4

5.7

400

1/8

1.3

1/2

6.9

500

1/4

5.7

1/2

6.9

700

1/2

6.9

1

14.0

850

1/2

6.9

1

14.0

Soft

Water Heater Pump Sizes

Hard

Medium

HP

Amps

HP

Amps

HP

Amps

XFyre

Model

*Current Draw is for heater only.
(Supply breaker must have delayed trip.)

Do not use when

hardness exceeds

15 grains per gallon

Summary of Contents for XFYRE 500

Page 1: ...up to 99 Efficiency Can be vented with PVC MBTU Models 300 400 500 700 850 CSA Verified lead Content Less Than 25 Pb Ultra Low Emissions...

Page 2: ...n ensures efficiency is maintained throughout the firing rate and actually increases during part load right when you want it The XFyre automatically self tunes to accommodate the widest range of gas s...

Page 3: ...h flexibility XFyre is the right boiler for almost any size job 6 Intake Air Filter Every XFyre comes standard with a front access removable Merv 8 media combustion air filter 7 Manual Reset High Limi...

Page 4: ...iler Control Raypak uses German made high quality Dungs gas valves considered the finest modulating gas valves produced today To the right of the gas valve is the boiler computer control center which...

Page 5: ...Input Minimum Input 300 300 282 94 300 285 95 60 400 399 375 94 399 379 95 80 500 500 470 94 500 475 95 100 700 700 658 94 700 665 95 140 850 850 799 94 850 808 95 170 Model Dimensions in A Length Am...

Page 6: ...GPM DP GPM DP GPM DP DT DP MTS DT GPM SHL GPM MTS DP SHL Do not use when hardness exceeds 15 grains per gallon MTS Minimum Tube Size inch SHL System Head Loss ft based on heater and tank placed no mo...

Page 7: ...tdoor Sensor Line Voltage Blocked Vent Low Water Level 24 Volt Low Low Water Flow Temper Blocking High Temperature Flue Gas Pressure Supply Thermistor Return Thermistor Supply High Ignition Control Fa...

Page 8: ...r Reset Sensor N A V Multiple Boiler Controller TempTracker Mod Hybrid up to 16 boilers groups V V Direct Spark Ignition System 1 try V V 4 try v v High Low Gas Pressure Switches V V Blocked Vent Swit...