6
3. BEFORE INSTALLATION
Receiving equipment
The manufacturer recommends that this manual be
reviewed thoroughly before installing the pool/spa heater. If
there are any questions that this manual does not answer,
please contact the factory or your local representative.
On receipt of your equipment visually check for external
damage to the carton. If the carton is damaged, a note
should be made on the Bill of Lading when signing for
the equipment. Remove the heater from the carton. If it is
damaged, report the damage to the carrier immediately.
Save the carton.
These items are shipped inside a box in the carton with
the heater:
Standard Unit (POLYMER HEADERS)
1. “Pagoda” top
2.
2" CPVC union half with "O" rings (2)
3. Plastic pipe finish flange for gas line
4.
Bonding lug with mounting screw (Digital) models
only)
ASME Unit (BRASS HEADERS)
1. “Pagoda” top
2.
2" CPVC union half with "O" rings (2)
3. Plastic pipe finish flange for gas line
4.
Bonding lug with mounting screw (Digital models
only)
5.
Pressure Relief Valve (PRV)
6.
Protek Shield™ Adapter with Protek Shield Assy,
O-ring and wing nut
F10640-1
MODEL AND SERIAL
NO. LOCATED ON
RATING PLATE
THE MODEL AND SERIAL NO. CAN
ALSO BE FOUND INSIDE THE
BEZEL ABOVE THE DISPLAY
Figure 1. Rating Plate Location
Be sure that you receive the number of packages indicated
on the Bill of Lading.
Rating and certifications
These heaters are design-certified and tested under the
latest requirements of the ANSI Z21.56 / CSA 4.7 Standard
for Gas-Fired Pool Heaters. All heaters can be used either
indoor or outdoors when appropiate venting is installed.
The appropriate top designated for each type of use is
required. If necessary, the top can be changed at a later
date to change from outdoor to indoor or vice versa.
All brass header units have heat exchangers which are
ASME-certified (BPV Section IV part HLW) and are
registered with National Board.
Elevation
Rated inputs are suitable for up to 2,000 ft (610 m)
elevation. For elevations above 2,000 ft (610 m), reduce
input 4% for each 1,000 ft (305 m) above sea level, as high
elevation reduces combustion performance.
Ambient Temperature Rating
Heater Components
Millivolt Heater with Honeywell Gas Valve 32°F to 175°F
(0°C to 79°C)
Millivolt Heater with Robertshaw Gas Valve 0°F to 175°F
(-18°C to 79°C)
Electronic Ignition Heater* -32°F to 175°F (-35°C to 79°C)
*Requires 120 or 240VAC, 1 Ph, 60 Hz Power Supply
6000.59AG_Atmospheric.indd 6
11/22/2019 9:50:08 AM
Summary of Contents for 206A
Page 24: ...24 6 WIRING DIAGRAM MILLIVOLT 6000 59AG_Atmospheric indd 24 11 22 2019 9 50 22 AM...
Page 25: ...25 7 WIRING DIAGRAM DIGITAL 6000 59AG_Atmospheric indd 25 11 22 2019 9 50 23 AM...
Page 51: ...51 NOTE 6000 59AG_Atmospheric indd 51 11 22 2019 9 50 40 AM...