12
Specifications and Dimensions
F10646
B
D
J*
A
C
Indoor
Drafthood
38”
(965 mm)
26-5/8”
(676 mm)
28-5/8” ASME
(727 mm ASME)
13-1/4”
(337 mm)
gas
connection
Figure 8. Front View
F10646-4
10"
(254 mm)
8-7/8"
(225 mm)
6-5/8" ASME
(168 mm ASME)
4-3/8
"
(111 mm)
(3-3/8" ASME)
(86 mm ASME)
32-11/16
"
(830 mm)
Electrical
Connection
28
"
(711 mm)
40
"
(1016 mm)
Stackless
Outdoor Top
CL
Flue
Amp Draw
120 VAC, 1Ph, 60Hz
240 VAC, 1Ph, 60Hz
4
2
Figure 9. Side View
Residential - Copper Heat Exchanger
Shipping Weights
lbs (kg)
Heater
Mode
BTUH
Input
(000)
(kw)
(A)
Cabinet
Width
in. (mm)
(B)
Flue
Dia.
in. (mm)
(C)
Indoor
Drafthood
in. (mm)
(D)
in. (mm)
(J)*
in. (mm)
Gas
Conn.
in.
Water
Conn.
in.
Standard
Heater
w/Stackless
Top
Indoor
Draft-
hood
206A
199.5
(58.4)
20
(508)
6
(152)
61-5/8
(1565)
10.0
(254)
11-3/4
(298)
3/4
2
187
(85)
14
(6.4)
266/266A
266.0
(77.9)
23
(584)
7
(178)
62
(1575)
11.5
(292)
11
(279)
3/4
2
210
(95)
16
(7.3)
336A
332.5
(97.4)
26
(660)
8
(203)
63
(1600)
13
(330)
10-5/8
(270)
3/4
2
230
(104)
19
(8.6)
399/406A
399
(116.9)
29
(737)
9
(229)
64-9/16
(1640)
14.5
(368)
12-1/8
(309)
3/4
2
249
(113)
21
(9.5)
Table G.
Residential - Copper Heater Specifications and Dimensions
*Note: For outdoor stack, use J dimension in the following tables for appropriate size
plus
6 inches (152 mm).
6000.59AG_Atmospheric.indd 12
11/22/2019 9:50:10 AM
Summary of Contents for 206A
Page 24: ...24 6 WIRING DIAGRAM MILLIVOLT 6000 59AG_Atmospheric indd 24 11 22 2019 9 50 22 AM...
Page 25: ...25 7 WIRING DIAGRAM DIGITAL 6000 59AG_Atmospheric indd 25 11 22 2019 9 50 23 AM...
Page 51: ...51 NOTE 6000 59AG_Atmospheric indd 51 11 22 2019 9 50 40 AM...
Page 52: ...6000 59AG_Atmospheric indd 52 11 22 2019 9 50 40 AM...