Chapter 5: Installation
43
• If the supplied power lead is too short, the lead can be extended if
required. The table shows the minimum acceptable cable sizes:
Hydraulic
Cable Length
Copper Area
AWG
Up to 2.5 m (8 ft).
2.5 mm
2
14
Up to 4 m (13 ft)
4 mm
2
12
Sterndrive
Cable Length
Copper Area
AWG
Up to 2.5 m (8 ft).
1 mm
2
18
Up to 4 m (13 ft)
1.5 mm
2
16
Up to 6 m (19.5 ft)
2.5 mm
2
14
Note:
Correct cable size is critical for correct autopilot operation. If
the cable is too small, a voltage drop will occur between the supply and
the control head. This will reduce the power to the drive, causing
slower response to course changes and corrections.
Connection to the SeaTalk bus
SeaTalk cables are not supplied with the equipment, as different
installations have different cabling requirements.
SeaTalk cables
The following table lists the standard SeaTalk cables available from
your
Raymarine
dealer:
Part No:
Description
D187
Flat to a male round connector – 0.15 m (6 in) long
D188
Flat to a female round connector – 0.3 m (12 in) long
D284
Flat moulded plugs at both ends – 1 m (3 ft 3 in) long
132_4c05.p65
14/06/99, 10:34
43
Summary of Contents for ST5000+
Page 2: ......
Page 41: ...Chapter4 CustomisingtheST5000Plus 29 1 1 OR D3583 1a...
Page 48: ...36 ST5000PlusSterndrive HydraulicAutopilotsOwner sHandbook...
Page 92: ...80 ST5000PlusSterndrive HydraulicAutopilots...
Page 94: ...82 ST5000PlusSterndrive HydraulicAutopilotsOwner sHandbook...
Page 100: ...88 ST5000 Plus Sterndrive and Hydraulic Autopilots Owner s Handbook...
Page 102: ......
Page 103: ...Shaded area to be removed TOP 109 mm Flush Mount Template 114 mm 4 holes 6 mm diameter D4437 2...
Page 104: ......
Page 105: ...RUDDER POSITIONED AMIDSHIPS CABLE POSITION DRILL THREE 3MM 1 8IN HOLES D3440 1...
Page 106: ......
Page 107: ......
Page 108: ...www raymarine com...