7.1 User calibration
The i60 CH instrument display is a repeater display
and as such does not require calibration, the steps
below apply to the calibration of the i60 Wind
instrument only.
User calibration options include:
• Wind angle offset — Assigns an offset to the wind
angle readings.
• Units for Wind speed readings — Assigns the unit
of measure used for wind speed related readings
Automatic Linearization
The wind transducer can linearize itself automatically
under certain conditions.
For Automatic Linearization to be performed
CAL
must be flashing on the digital display. CAL is
displayed for approximately 30 seconds after power
on under the following conditions:
• At first power on, after installation
• At power on, after a factory reset.
To perform the automatic linearization the vessel will
need to be underway, with sufficient space to turn in
large circles unhindered. The wind speed must be
sufficient to hold the vane to wind whilst the vessel is
turning. The vessel must be turned slowly through at
least 2 complete circles.
x 2
D12415-2
This procedure automatically linearizes the wind
vane. A successful linearization is indicated by the
digital display flashing and a buzzer sounding three
beeps
Accessing the User Calibration Menu
The User Calibration Menu can be accessed by
following the steps below.
During normal operation:
1. Press and hold the
Display
and
True / App
buttons at the same time for approximately
2 seconds, until the User Calibration page is
displayed.
+
D12488-2
1
0
15
20
25
30
35
40
45
50
55
60 5
2
Disp
lay
T
rue /App
Aligning the wind transducer
From the User Calibration Menu:
1. Press the
Display
button until the
Wind Angle
Offset
page is displayed (1 press from the
User
Calibration
page).
D12489-2
Disp
lay
2. Sail your vessel directly into the wind and adjust
the analog pointer to zero, using the
VMG
and
Tack
buttons.
D12490-2
V
MG
T
a ck
The VMG button will decrease the current value
and the Tack button will increase the current
value. As you do this, the wind angle offset
shows the amount of correction you have applied.
3. To exit the User Calibration Menu at any time
press and hold the
Display
and
True / App
buttons at the same time for approximately 2
seconds.
Selecting the unit of measure for wind speed
readings
From the User Calibration Menu:
1. Press the
Display
button until the
Wind Speed
Units
page is displayed (2 presses from the
User
Calibration
page).
D12491-2
Disp
lay
2. Use the
VMG
or
Tack
buttons to select the
required unit of measure for wind speed readings.
The available units of measure for wind speed
are:
•
KTS (default)
— Knots
•
M/S
— Meters per second
3. To exit the
User Calibration
pages at any time
press and hold the
Display
and
True / App
buttons at the same time for approximately 2
seconds.
38
i60
Summary of Contents for i60 wind
Page 2: ......
Page 4: ......
Page 6: ...6 i60...
Page 10: ...10 i60...
Page 14: ...14 i60...
Page 22: ...22 i60...
Page 32: ...32 i60...
Page 36: ...36 i60...
Page 42: ...42 i60...
Page 47: ...Chapter 9 Alarms Chapter contents 9 1 Alarms on page 48 Alarms 47...
Page 58: ...58 i60...
Page 66: ...66 i60...
Page 68: ...68 i60...
Page 69: ......
Page 70: ...www raymarine com...