Fuse / Breakers
• 12 V system: 8 A thermal breaker
or 12 A rated fuse.
• 24 V system: 4 A thermal breaker
or 6 A rated fuse.
Current
G120
• 4 A @12 Vdc
• 2 A @24 Vdc
G150
• 4 A @12 Vdc
• 2 A @24 Vdc
G170
• 7.6 A @12 Vdc
• 3.5 A @24 Vdc
G190
• 7.7 A @12 Vdc
• 3.6 A @24 Vdc
Mechanical
Weight
• G120: 4.6 kg (10 lb)
• G150: 5.8 kg (12 lb)
• G170: 6.4 kg (14 lb)
• G190: 7.3 kg (16 lb)
D
11893-1
G
120
G150
330 mm
(13.00”
)
A
380 mm
(14.97”)
284 mm
(11.18”)
B
315 mm
(12.39”)
307 mm
(12.08”)
C
357 mm
(14.07”)
257 mm
(10.10”)
D
292 mm
(11.5”)
118 mm
(4.64”)
118 mm
(4.64”)
E
G170
415 mm
(16.34”)
G190
454 mm
(17.87”)
358 mm
(14.10”)
394 mm
(15.51”)
335 mm
(13.19”)
100 mm
(3.94”)
389 mm
(15.31”)
432 mm
(17.00”)
366 mm
(14.41”)
100 mm
(3.94”)
A
E
C
D
B
Environmental
Environmental
• Operating temperature: -10 ºC to
+50 ºC (14 ºF to 122 ºF)
• Relative humidity: max 95%
• Water proof to IPX6 (rating applies
to front of monitor).
154
G-Series installation instructions
Summary of Contents for G-Series system
Page 1: ...G Series system Installation instructions...
Page 2: ......
Page 4: ......
Page 8: ...8 G Series installation instructions...
Page 14: ...14 G Series installation instructions...
Page 98: ...98 G Series installation instructions...
Page 124: ...124 G Series installation instructions...
Page 142: ...142 G Series installation instructions...
Page 146: ...146 G Series installation instructions...
Page 158: ...158 G Series installation instructions...
Page 180: ...www raymarine com...