8.14 DSM400 sonar LED indications
LED indications associated with the DSM400 sonar unit are
described here.
LED state
Possible causes
1 flashing (500 / 500 ms) green LED.
Normal operation (Heartbeat).
1 flashing (750 / 250 ms) green LED.
Standby mode.
Off for < 2 minutes.
Startup.
Off for > 2 minutes.
No power.
1 steady amber LED.
• Power on.
• Lamp test.
1 flashing amber LED.
Input transducer.
2 flashing amber LEDs.
No network / cable unplugged.
3 flashing amber LEDs.
Overheating warning.
8 flashing amber LEDs.
Watchdog restart.
Flashing (750 / 250 ms) LEDs
alternating between amber and red.
Retrieving software from memory
card. This condition remains until a
valid application is available from the
memory card.
1 flashing red LED.
Voltage error.
3 flashing red LEDs.
Overheating error.
4 flashing red LEDs.
Flash write error.
5 flashing red LEDs.
No application programmed.
8 flashing red LEDs, possibly followed
by flashing amber.
Hardware read error.