1.
Waterproof fuse holder with 5 A inline fuse must be fitted (not supplied).
2. SeaTalkng ® power cable.
3.
Drain wire connection point.
Battery connection scenario A:
Suitable for a vessel with a common RF ground point. In this scenario, the power cable’s drain wire
should be connected to the vessel’s common RF ground point.
Battery connection scenario B:
Suitable for a vessel without a common RF ground point. In this scenario the power cable’s drain wire
should be connected directly to the battery’s negative terminal.
SeaTalkng ® Power cable extension
If you need to extend the length of the SeaTalkng ® power cable, ensure you use suitably rated cable
and that sufficient power is available at the SeaTalkng ® backbone’s power connection point:
• For power cable extensions, a
minimum
wire gauge of 16 AWG (1.31 mm
2
) is recommended. For
cable runs longer than 15 meters, you may need to consider a thicker wire gauge (e.g. 14 AWG
(2.08 mm
2
), or 12 AWG (3.31 mm
2
) ).
• An important requirement for all lengths of power cable (including any extension) is to ensure that
there is a continuous
minimum
voltage at the product’s power connector of 10.8 V dc, with a
fully flat battery at 11 V dc.
Important:
Be aware that some products in your system (such as sonar modules) can create voltage peaks at
certain times, which may impact the voltage available to other products during the peaks.
More information
It is recommended that best practice is observed in all vessel electrical installations, as detailed
in the following standards:
• BMEA Code of Practice for Electrical and Electronic Installations in Boats
• NMEA 0400 Installation Standard
64
Summary of Contents for Evolution EV-1
Page 2: ......
Page 4: ......
Page 34: ...Item Description Quantity 4 Mounting screws 2 5 Document pack 1 34...
Page 36: ...5 1 Dimensions EV 1 and EV 2 36...
Page 37: ...5 2 Dimensions ACU 100 ACU 150 Product dimensions 37...
Page 38: ...5 3 Dimensions ACU 200 ACU 300 ACU 400 38...
Page 54: ...54...
Page 66: ...66...
Page 80: ...Item Wire color ACU 100 ACU 150 1 Red 2 Blue 3 Green 4 Gray screen 80...
Page 82: ...82...
Page 104: ...104...
Page 114: ...114...
Page 128: ...128...
Page 134: ...134...
Page 138: ......
Page 141: ......