4. Rotate the locking collar clockwise (2 clicks) until it is in the locked position.
9.4 Power connection — EV-1
The power for the EV-1 unit is provided by the SeaTalkng ® backbone.
• The EV-1 unit must be connected to a spur connection on the SeaTalkng ® backbone.
• SeaTalkng ® requires ONE 12 V dc power source. This can be provided by:
– A battery
– An Evolution ACU–200, ACU-300 or ACU-400 providing power to the same SeaTalkng ®
backbone.
If your vessel has a 24 V supply a suitable voltage convertor is required.
Warning: Positive ground systems
Do not connect this unit to a system which has positive grounding.
9.5 SeaTalkng ® power connection point
The 12 V dc power supply is connected to a spur connection on the SeaTalkng ® backbone.
Large systems
If the backbone length is greater than 60 m (197 ft), the power connection point should be connected
at a point that creates a balanced current draw from each side of the backbone. The NMEA 2000
Load Equivalency Number (LEN) is used to determine the power connection point for the backbone.
In the example above the backbone has an overall LEN of 10, so the optimum connection point would
be to have 5 LEN either side of the connection point.
60
Summary of Contents for Evolution EV-1
Page 2: ......
Page 4: ......
Page 34: ...Item Description Quantity 4 Mounting screws 2 5 Document pack 1 34...
Page 36: ...5 1 Dimensions EV 1 and EV 2 36...
Page 37: ...5 2 Dimensions ACU 100 ACU 150 Product dimensions 37...
Page 38: ...5 3 Dimensions ACU 200 ACU 300 ACU 400 38...
Page 54: ...54...
Page 66: ...66...
Page 80: ...Item Wire color ACU 100 ACU 150 1 Red 2 Blue 3 Green 4 Gray screen 80...
Page 82: ...82...
Page 104: ...104...
Page 114: ...114...
Page 128: ...128...
Page 134: ...134...
Page 138: ......
Page 141: ......