10.5 Self-test
The unit has a built in self-test to aid fault diagnosis. The resulting
failures and / or fault codes should be used when contacting
Raymarine customer support.
Starting self-test — i50 Depth
1. Press and hold the
Depth
and
Reset
buttons simultaneously for
4 seconds, until the unit beeps.
2. When the unit beeps immediately press
Offset
and
Reset
buttons simultaneously to start self test stage 1.
3. To progress to the next self-test stage press the
Depth
and
Alarm
buttons simultaneously.
Starting self-test — i50 Speed
1. Press and hold the
Speed
and
Reset
buttons simultaneously for
4 seconds, until the unit beeps.
2. When the unit beeps immediately press
Timer
and
Reset
buttons simultaneously to start self test stage 1.
3. To progress to the next self-test stage press the
Speed
and
Trip
buttons simultaneously.
Starting self-test — i50 Tridata
1. Press and hold the
Depth
and
Reset
buttons simultaneously for
4 seconds, until the unit beeps.
2. When the unit beeps immediately press
Trip
and
Reset
buttons
simultaneously to start self test stage 1.
3. To progress to the next self-test stage press the
Depth
and
Speed
buttons simultaneously.
Self-test stages
The self-test comprises of the following stages
Self-test stage 1
When entering
Self-test stage 1
, the unit beeps and the display
shows
TEST 1
, for 1 second.
Self-test stage 1
will perform the following tests:
• SeaTalk / SeaTalk
ng
self-test, which checks the receive and
transmit circuits.
• EEPROM test (read and write).
If the tests are satisfactory,
PASS
is shown on the display.
If the tests are not satisfactory, the following failure codes may be
generated:
Fault code
FAIL 1
FAIL 2
Self-test stage 2
When entering
Self-test stage 2
, the unit beeps and the display
shows
TEST 2
, for 1 second.
Self-test stage 2
will perform the following tests:
• Backlighting test, which cycles between on and off every second.
• Any button press sounds a beep.
• Display test, which tests the LCD segments in the following
sequence, changing once per second:
1
2
D
12548-1
1
i50 Depth, i50 Speed
2
i50 Tridata
While the test is progressing, press each of the display buttons and
check that the buzzer sounds as each button is pressed.
The table below shows possible problems that may be encountered:
Failure
No illumination.
Button illumination failure.
No beep when button pressed.
LCD segment(s) missing completely.
Faint LCD segment(s).
Self-test stage 3
Note:
After
Self-Test stage 3
is not supported on this unit,
progressing from
Self-test stage 2
will start
Self-test stage 4
.
Self-test stage 4
A known good transducer must be connected for
Self-test stage 4
,
and the vessel must be underway at sufficient speed for the tests to
be performed.
When entering
Self-test stage 4
, the unit beeps and the display
shows
TEST 4
, for 1 second.
Self-test stage 4
will perform a transducer test
If the test is satisfactory then PASS is shown on the display.
If the test is not satisfactory then a fail code will be shown on the
display:
Fault code
Transducer
FAIL 10
Speed
FAIL 8
Depth
To exit self-test stage 4, press the
Up
and
Down
buttons
simultaneously.
56
i50
Summary of Contents for E70058
Page 2: ......
Page 4: ......
Page 6: ...6 i50 ...
Page 18: ...18 i50 ...
Page 24: ...24 i50 ...
Page 38: ...38 i50 ...
Page 45: ...Chapter 8 Using alarms Chapter contents 8 1 Alarms on page 46 Using alarms 45 ...
Page 64: ...13 4 Converters Part number Description E22158 SeaTalk to SeaTalkng Converter 64 i50 ...
Page 66: ...66 i50 ...
Page 67: ......
Page 68: ...www raymarine com ...