7. Use the
Timer
or
Reset
buttons to select the required speed
log units.
8. Press the
Speed
button to display one of the current speed
pages, if SOG data is available over SeaTalk then the SOG page
is displayed, if SOG data is not available then the cal factor
page is displayed.
D12430-1
S pe e d
S pe e d
S
OG
S
OG
9. Press the
Timer
and
Reset
buttons simultaneously to switch
between the cal factor and SOG pages.
D12431-1
Re s e t
Time r
+
10. If the SOG page is displayed and the tide conditions are slack,
press and hold the
Reset
button for 3 seconds to accept SOG
as the current speed.
D12432-1
Re s e t
1
0
15
20
25
30
35
40
45
50
55
60 5
3
11. Alternatively, with the cal factor page displayed use the
Timer
or
Reset
buttons to set the cal factor to your vessel's estimated
current speed.
12. Press the
Speed
button to display the temperature units page.
D12434-1
S pe e d
13. Use the
Timer
or
Reset
buttons to select the required
temperature units.
14. Press the
Speed
button to display the temperature calibration
page.
D12435-1
S pe e d
15. Use the
Timer
or
Reset
buttons to set the unit to show the
current water temperature.
16. Press the
Speed
button to display the Timer buzzer page.
D12436-1
S pe e d
17. Use the
Timer
or
Reset
buttons to switch the count-up and race
start timer buzzers on and off.
18. To exit the user calibration pages at any time, press and hold the
Speed
and
Trip
buttons simultaneously for 2 seconds.
Calibrating i50 Tridata
1. Press and hold down the
Depth
and
Speed
buttons
simultaneously for approximately 2 seconds to display the user
calibration entry page.
D12438-1
De pth
S pe e d
+
1
0
15
20
25
30
35
40
45
50
55
60 5
2
Note:
The user calibration entry screen will time-out after 8
seconds of inactivity.
Calibrating i50 Tridata depth
From the User calibration entry page:
1. Press the
Depth
button to display the depth units page.
D12439-1
De pth
2. Use the
Trip
or
Reset
buttons to select the required depth units.
3. Press the
Depth
button to display the depth offset page.
D12440-1
De pth
4. Use the
Trip
or
Reset
buttons to set the required depth offset.
5. Press the
Depth
button to display the shallow alarm lock page.
D12441-1
De pth
6. Use the
Trip
or
Reset
buttons to switch the shallow alarm lock
on and off.
7. To exit the user calibration pages at any time, press and hold the
Depth
and
Speed
buttons simultaneously for 2 seconds.
Calibrating i50 Tridata speed
During normal operation:
1. Press the
Speed
button to display the speed units page.
D12442-1
S pe e d
2. Use the
Trip
or
Reset
buttons to set the required speed units.
3. Press the
Speed
button to display the speed resolution page.
D12443-1
S pe e d
4. Use the
Trip
or
Reset
buttons to set the required speed
resolution.
5. Press the
Speed
button to display the speed log units page.
D12444-1
S pe e d
6. Use the
Trip
or
Reset
buttons to select the required speed log
units.
7. Press the
Speed
button to display one of the current speed
pages, if SOG data is available over SeaTalk then the SOG page
is displayed, if SOG data is not available then the cal factor
page is displayed.
D12445-1
S
OG
S
OG
S pe e d
S pe e d
8. Press and hold down the
Trip
and
Reset
buttons simultaneously
to switch between the cal factor and SOG pages.
D12446-1
Re s e t
Trip
+
Getting started
33
Summary of Contents for E70058
Page 2: ......
Page 4: ......
Page 6: ...6 i50 ...
Page 18: ...18 i50 ...
Page 24: ...24 i50 ...
Page 38: ...38 i50 ...
Page 45: ...Chapter 8 Using alarms Chapter contents 8 1 Alarms on page 46 Using alarms 45 ...
Page 64: ...13 4 Converters Part number Description E22158 SeaTalk to SeaTalkng Converter 64 i50 ...
Page 66: ...66 i50 ...
Page 67: ......
Page 68: ...www raymarine com ...