• The text START 2 alternating with the new calibration factor is
displayed at the top of the page.
• The displayed distance freezes
D12468-1
S pe e d
Note:
The displayed distance should be very close to the actual
(measured) distance of the calibration run.
9. If you are satisfied with the results of the first calibration run,
press the
Depth
and
Speed
buttons simultaneously to save the
new calibration factor, exit speed calibration and return to the
status page.
10. If you want to carry out a second calibration run, press the
Speed
button.
11. Follow steps 5 to 7 above again to complete a second calibration
run.
12. At the end of the return leg press the
Speed
button
At this point:
• The text END alternating with the new calibration factor is
displayed at the top of the page.
• The displayed distance freezes.
D12469-1
S pe e d
13. To exit the speed calibration run at any time, press and hold the
Depth
and
Speed
buttons simultaneously for 4 seconds.
Dealer calibration
The dealer calibration procedures include:
i50 Depth
i50 Speed
i50 Tridata
Setting User calibration
options on or off.
Setting User calibration
options on or off.
Setting User calibration
options on or off.
Setting required depth
response.
Setting required speed
response.
Setting data source for
speed information.
Setting boat show mode
on or off.
Setting required VMG
response.
Setting required speed
response.
Restore factory default
Setting boat show mode
on or off.
Setting required depth
response.
Restore factory default
Setting boat show mode
on or off.
Restore factory default
Setting dealer calibration options – i50 Depth
During normal operation:
1. Press and hold the
Depth
and
Alarm
buttons simultaneously
for approximately 14 seconds to display the dealer calibration
entry page.
De pth
+
Ala rm
D12470-1
1
0
15
20
25
30
35
40
45
50
55
60 5
14
2. Press the
Offset
and
Reset
buttons simultaneously to display
the user calibration access page.
+
D12470-1
Re s e t
Offs e t
3. Use the
Offset
or
Reset
buttons to switch the user calibration
on and off.
4. Press the
Depth
button to display the depth response page.
D12472-1
De pth
5. Use the
Offset
or
Reset
buttons to set the required depth
response setting.
6. Press the
Depth
button to display the boat show mode page.
D12473-1
De pth
7. Press the
Depth
button to display the factory reset page.
D12474-1
De pth
8. Use the
Offset
or
Reset
buttons to reset the units settings to
factory default values.
9. To exit the dealer calibration pages at any time, press and hold
the
Depth
and
Alarm
buttons simultaneously for approximately
2 seconds.
Setting dealer calibration options - i50 Speed
During normal operation:
1. Press and hold the
Speed
and
Trip
buttons simultaneously
for approximately 14 seconds to display the dealer calibration
entry page.
S pe e d
+
Trip
D12475-1
1
0
15
20
25
30
35
40
45
50
55
60 5
14
2. Press the
Timer
and
Reset
buttons simultaneously to display
the user calibration access page.
+
D12476-1
Re s e t
Time r
3. Press the
Speed
button to display the speed response page.
D12477-1
S pe e d
4. Use the
Timer
or
Reset
buttons to set the required speed
response value.
5. Press the
Speed
button to display the speed VMG response
page.
D12478-1
S pe e d
6. Use the
Timer
or
Reset
buttons to set the required VMG
response value.
7. Press the
Speed
button to display the boat show mode page.
D12479-1
S pe e d
8. Use the
Timer
or
Reset
buttons to switch boat show mode on
and off.
9. Press the
Speed
button to display the factory reset page.
D12480-1
S pe e d
10. Use the
Timer
or
Reset
buttons to reset the units settings to
factory default values
11. To exit the dealer calibration pages at any time, press and hold
the
Speed
and
Trip
buttons simultaneously for approximately
2 seconds.
36
i50
Summary of Contents for E70058
Page 2: ......
Page 4: ......
Page 6: ...6 i50 ...
Page 18: ...18 i50 ...
Page 24: ...24 i50 ...
Page 38: ...38 i50 ...
Page 45: ...Chapter 8 Using alarms Chapter contents 8 1 Alarms on page 46 Using alarms 45 ...
Page 64: ...13 4 Converters Part number Description E22158 SeaTalk to SeaTalkng Converter 64 i50 ...
Page 66: ...66 i50 ...
Page 67: ......
Page 68: ...www raymarine com ...