60
Logger running
status
Light o
ff
: Running abnormally.
On 1s/Off 1s (Slow flash): Running normally.
On 100ms/Off 100ms (Fast flash): Restore factory settings.
The normal operation status of the stick logger, when router connected to the network
normally:
1. Successful connection status with serve: NET light keeps on after the logger powered
on.
2. Logger running normally: READY light Flashes.
3. Successful connection status with inverter: COM light keeps on.
6.4 Abnormal State Processing
If the data on platform is abnormal when the stick logger is running, please check the table
below and according to the status of indicator lights to complete a simple troubleshooting.
If it still can not be resolved or indicator lights status do not show in the table below,
please contact our Customer Service..(Note: Please using the following table query after
power-on for 2mins at least.)
NET
COM
READY
Fault Description
Fault Cause
Solution
Any
state
OFF
Slow
flash
Communicate with
inverter abnormally
1.Connection betw-
een stick logger and
inverter loosen.
Inverter does not
match with stick log-
ger's communication
rate.
1. Check the connection between
stick logger and inverter. Remove the
stick logger and install again.
2. Check inverter's communication
rate to see if it matches with stick
logger's.
3. Long press Reset button for
5s, reboot stick logger.
OFF
ON
Slow
flash
Connection
between logger and
router abnormal
1.Stick logger does
not have a network.
2.Antenna abnormal
3.Router WiFi signal
strength weak.
1.Check if the wireless network
configured.
2.Check the antenna, if there is any
damage or loose.
3.Enhance router Wi-Fi signal
strength. Long press Reset button for
10s, reboot stick logger and
networking again.
Slow
flash
ON
Slow
flash
Connection betwe-
en logger and router
normal, connection
between logger and
remote server
abnormal.
1. Router networking
abnormal.
2. The server point
of logger is modified.
3.Network limitation,
server cannot be
connected.
1.Check if the router has access to
the network.
2.Check the router's setting, if the
connection is limited.
Summary of Contents for RI-ENERGYFLOW-3P-MODULAR...
Page 4: ...4...
Page 12: ...12 Accessory Cable PACK10 2 Accessory Cable PACK20 4 Accessory Cable PACK30 6...
Page 13: ...13 Accessory Cable PACK40 8...
Page 14: ...14...
Page 28: ...28 Figure 17 Wiring the Communication Cable...
Page 30: ...30 Figure 19 PV Wiring Step12 Close the lid and tighten the screw Figure 20...
Page 58: ...58...