background image

编号

RFL-

C20000XZ-

JS01

密级

1

阶段标记

S

页数

85

名称

RFL-C20000XZ

连续光纤激光器

英文版使用说明书

朱超

单位

连续激光器技术研究部

谢良

编写

阮勇

校对

刘阳

审核

王建明

标审

李其军

批准

王建明

武汉锐科光纤激光技术股份有限公司

Summary of Contents for RFL-C20000XZ

Page 1: ...编号 RFL C20000XZ JS01 密级 内 1 阶段标记 S 页数 85 名称 RFL C20000XZ 连续光纤激光器 英文版使用说明书 朱超 单位 连续激光器技术研究部 谢良 编写 阮勇 校对 刘阳 审核 王建明 标审 李其军 批准 王建明 武汉锐科光纤激光技术股份有限公司 ...

Page 2: ...RFL C20000XZ Continuous Wave Fiber Laser User Guide ...

Page 3: ...Wuhan Raycus Fiber Laser Technologies Co Ltd ...

Page 4: ...RATION ENVIRONMENT 5 2 5 ATTENTIONS 5 2 6 SPECIFICATIONS 6 3 INSTALLATION 7 3 1 DIMENSIONS 7 3 2 INSTALLATION RULE 9 3 3 PROTECTIVE END CAP OF OUTPUT CABLE AND USING DESCRIPTIONS 11 3 3 1 Category and ex factory for protective end cap 11 3 3 2 Cleaning Description before Installation 13 3 4 COOLING REQUIREMENTS 17 4 USING THE PRODUCT 19 4 1 FRONT PANEL 19 4 2 REAR PANEL 21 4 3 POWER CONNECTION 24 ...

Page 5: ... 3 Red light control 43 5 6 4 Programming mode 43 6 WIRING DIAGRAM AND OPERATION STEPS 44 6 1 INTERNAL CONTROL IN ON MODE 44 6 2 EMISSION EXTERNAL CONTROL MODE SET BY POWER COMMUNICATION IN ON MODE 45 6 3 EMISSION EXTERNAL CONTROL SET BY POWER ANALOG IN ON MODE 46 6 4 EMISSION EXTERNAL CONTROL THROUGH PROGRAMMING MODE ON THE ON MODE 47 6 5 SET THE POWER ANALOG AS EMISSION EXTERNAL CONTROL ON THE R...

Page 6: ...SER PARAMETER DISPLAY AREA 66 8 5 ALARM TYPE DISPLAY AREA 67 8 6 PC SOFTWARE OPERATING MODE SELECTION 67 8 7 LANGUAGE 69 8 8 AUTHORIZATION TIME LIMITED LOCKING 70 8 8 1 Authorization on user mode 70 8 8 2 Authorization on authorization mode 70 8 9 ABOUT 71 8 10 XP1 INTERFACE STATUS INDICATION IN DIAGNOSTIC MODE 72 8 11 LOG IN DIAGNOSTIC MODE 73 8 11 1 Download log 74 8 11 2 Downloadrecord of histo...

Page 7: ...Raycus Fiber Laser Technologies Co Ltd User Guide of RFL C20000XZ 8 13 5 Command Explanation 82 9 WARRANTY REPAIR AND RETURN 83 9 1 GENERAL WARRANTY 83 9 2 LIMITATIONS OF WARRANTY 84 9 3 SERVICE AND REPAIR 84 ...

Page 8: ...carefully review the following cautions and warnings as well as other information within this manual 1 1 Security Labels WARNING Describes a hazard that leads to severe personal injury or death CAUTION Describes a hazard that leads to general personal injury or damages to product English Chinese English 20000W Chinese 20000W English Chinese 1 Laser output Head 2 Type 4 Laser Product 3 Class 2 Lase...

Page 9: ...and certified laser safety glasses must be worn whenever the laser is emitting WARNING Users must use appropriate laser goggles when operating this device The laser goggles are selected according to the range of wavelength emitted from this product Users must select the appropriate laser goggles according to the entire range of laser wavelengths Please do not directly view the laser output head wh...

Page 10: ...ecified in this manual the protection provided by the device may be impaired and the warranty will be voided d There are no user serviceable parts equipment or assemblies inside the product All service and maintenance shall be conducted by a certified Raycus engineer In order to prevent electric shock please do not break the seal or uncover the shield Otherwise any damage to the device will not be...

Page 11: ...correctly placed before unpacking and there is no damage from phenomenon such as collision cracking and flooding on the outside of the box Once you find that there is an abnormality in the external cabinet please inform Raycus Company in time to deal with it as soon as possible Please double check if each listed object is inside the package and contact Raycus as soon as possible if there are any i...

Page 12: ...er optic cable Please inspect the output head carefully for dust or other contaminations Use appropriate lens paper to clean it if necessary c Failure to follow the instructions when operating the laser may cause malfunction and damage d It is not allowed to install the output head when the laser is in operation e Do not look directly into the output head Always wear appropriate protective eyeglas...

Page 13: ...se laser power loss and such loss is not covered by warranty 2 6 Specifications Table 2 Product Specifications Optical properties Test Conditions Model C20000XZ Output Power kW 20 Operation Mode CW Modulated Polarization State Random Output Power Tunability 10 100 Emission Wavelength nm 1080 5 Nominal Output Power Output Power Instability 1 5 Nominal Output Power Duration 5hrs Ambient Temp 25 Modu...

Page 14: ...57 Way to control Serial communication AD Other characteristics Dimension mm 1200 1610 1230 mm Includes casters and rings without warning lights Weight kg 800 Air conditioning included Operating Ambient Temperature C 10 40 Humidity 70 Storage temperature C 10 60 Cooling method Water cooling 3 Installation 3 1 Dimensions The main body dimensions of RFL C20000XZ continuous wave fiber laser are shown...

Page 15: ...us Fiber Laser Technologies Co Ltd User Guide of RFL C20000XZ 8 Figure 1 a Front and rear view of the laser Figure 1 b Top and left view of the laser Figure 1 the dimensions of RFL C20000XZ continuous fiber laser ...

Page 16: ...ble into the processing head the lens of the output cable must be inspected If the output cable lens is dirty the lens must be cleaned It is forbidden to disassemble the output lens by anyone other than staffs from Raycus otherwise the warranty will be invalidated 3 2 Installation rules a Place the laser horizontally in a suitable position and ground it as necessary b Before the laser is powered o...

Page 17: ... the laser is emitting light the minimum bending diameter shall not be less than 30cm i Customers can use the four lifting rings at the top of the product or the four casters at the bottom to lift or move the product Before lifting the laser source make sure that the four lifting rings are installed firmly and reliably When lifting the laser source be sure to use the four lifting rings when pushin...

Page 18: ...ng head cavity are clean and free of pollution 3 3 Protective end cap of output cable and using descriptions 3 3 1 Category and ex factory for protective end cap For multi module high power fiber laser the output optical cable model used is QBH QD QP output optical cable and there are two types of protective end caps with the device as shown in the figure Type A end cap it is assembled on the outp...

Page 19: ... C10000X QD A type end cap with protective window A type end cap with protective window RFL C12000X QD A type end cap with protective window A type end cap with protective window RFL C15000W QD A type end cap with protective window B type without protective window RFL C20000XZ QP A type end cap with protective window B type without protective window RFL C30000XZ QP A type end cap with protective w...

Page 20: ...t anhydrous ethanol or isopropanol 1 2 Cleaning tools cleaning swab dust free paper compressed air bottle etc b Operation steps 1 3 Open the air extraction for at least 5 minutes in advance before cleaning workbench and take out the output optical cable from the black packaging box as shown in figure 5 Blow air with a compressed air bottle on the outer surface of the shell for preliminary cleaning...

Page 21: ...e the following operations need to be carried out in a clean workbench If the operation is not carried out in a clean environment it will cause great risks to the QP output optical cable Operators should wear fingerstalls 1 Figure 6 output optical cable placed in cleaning workbench and with air extraction 2 Remove white anti dust cap and place it in a new dust free paper facing down ...

Page 22: ... cable and put it on the dust free paper Figure 8 remove A type end cap in the cable 4 In this state check the cleanliness of the end cap If the cleanliness is not enough please clean the end cap Please refer to the following cleaning methods http www raycuslaser com view 1852 html video reference https mp weixin qq com s hRXrPkb8DAyvDYegSWwYLg Note the end cap cleaning is generally operated by ou...

Page 23: ...re the cleanliness of the internal and external surfaces of the cutting head or welding head connector Note connecting with cutting head welding head needs to be carried out in a clean workbench it is necessary to check the cleanliness and finish of related components for the cutting head or welding head Keep the corresponding accessories as shown in figure 9 to facilitate the reoperation of the l...

Page 24: ...0 and the arrow direction indicates the water flow direction b Cooling water needs to be pure water c In order to prevent the water in the water cooler from growing mold and causing pipeline blockage it is recommended to add alcohol when filling pure water and the amount of alcohol added is 10 of pure water d When the ambient temperature of the equipment is between 10 and 0 the glycol solution wit...

Page 25: ...ter ϕ8 and inner diameter ϕ5 5 e Cooling water quality deionized water distilled water purified water it is recommended to replace the water once a month and the replacement period should not exceed two months f PH value of cooling water 5 5 9 g The water cooler needs to be equipped with a filter element whose filter particle size is less than 100um the filter element needs to be cleaned once a mo...

Page 26: ...t will be damaged c Please use compressed gas below 0 5MPa when emptying water from the device Failure to do so may cause permanent equipment damage to cooling system CAUTION 1 Set the water temperature of the cooling system correctly according to the ambient temperature Setting the water temperature too high will result in the laser not working properly Setting the water temperature too low will ...

Page 27: ...he laser POWER Control power indicator when the white indicator light is on it means the main control system is on LASER The power button of the laser main power supply has a green light indicator function After the laser main control system is powered on and all INTERLOCKs are detected as normal press this button the laser main power supply is powered on and the button lights up after the main po...

Page 28: ... to turn on the laser and power on the laser again to return to normal INDICATOR LIGHT After the main power supply of the laser is turned on the green indicator light is on when the laser is Ready when the laser is emitting light the red indicator light is on when the laser has a fault the yellow indicator light is on accompanied by an alarm sound 4 2 Rear Panel Figure 12 shows the rear panel ...

Page 29: ...aser Technologies Co Ltd User Guide of RFL C20000XZ 22 Figure 12 Rear view of product panel Note INTERFACE BREAKER AC INPUT FIBER WATER IN FIBER WATER OUT BOTTOM WATER IN FILTER TOP WATER IN TOP WATER OUT BOTTOM WATER OUT ...

Page 30: ...temperature water of the water cooler and connected to the φ 13 inner diameter water pipe FIBER WATER OUT Output fiber optic cable out of the water interface this interface is connected to the output fiber optic cable inlet connected to the φ13 inner diameter of the water BOTTOM WATER IN The lower water inlet of the laser this interface is connected to the outlet of the cooling water of the water ...

Page 31: ...ower supply meets the requirements in Table 1 2 Incorrect wiring will cause damage to the laser so please check whether the power cord is connected correctly before powering on the laser Figure 13 shows the power cord provided by Raycus Figure 13 RFL C20000XZ Laser source power cord Insert the plug at the end of the power cord into the socket marked AC INPUT on the rear panel Note that the plug ha...

Page 32: ...ce are shown in Table 5 Table 5 The interface definition and parameter requirements of AC input line Interface definition and parameter requirements of RFL C20000XZ AC input line Connector Tag Interface definition Logo Wire diameter Wire color 1 2 AC380V L1 L1 16mm2 Brown 1 2 3 4 5 6 7 3 4 AC380V L2 L2 16mm2 Black 8 9 10 11 12 13 14 5 6 AC380V L3 L3 16mm2 Gray 7 Protective PE 16mm2 Yellow green 8 ...

Page 33: ...The appearance of the joint is shown in Figure 15 Figure 15 Control signal line 4 4 1 Safety XP2 Interface 24 pin safety interface with remote control system power on remote main power power on and active and passive output of some lasers The detailed interface definition is shown in Table 6 HARDWIRING XP1 Security interface XP2 Analog interface XP4 Serial interface XP3 Communication Interface XP5...

Page 34: ...output passive contact current 100 mA voltage 30V The current panel stop press 11 14 open or short circuit 14 OUT 12 OUT Front panel emergency output 2 relay contact output passive contact current 100 mA voltage 30V The current panel stop press 12 13 open or short circuit 13 OUT 15 OUT FET S pole Main power supply power on output indication MOS pipe D S output current 0 5A voltage 30V passive sign...

Page 35: ...xternal control mode When the key switch hits REM and the laser is operating in outgoing light control mode MO D and XP1 A2 at this time the A2 bit outgoing light enable signal are jointly used to control the la ser output and off in REM mode outgoing light control can be controlled only by A2 to be customi zed b Passive light output indication and main power up indication XP2 s 3 4 light output i...

Page 36: ...XZ 29 Figure 17 Out light output and main power up indication circuit diagram Figure 18 Recommended wiring diagram for light output indication 12V as an example Customer 12v positive power supply Customer 12v negative power supply PIN PIN Indicator light 12V for example ...

Page 37: ...main power up indication 12V as an example c Active light out indication and main power up indication Figure 20 Active light out indication and main power supply has been powered on indication circuit diagram Customer 12v positive power supply Customer 12v negative power supply PIN PIN Indicator light 12V for example ...

Page 38: ...indication and main power supply has been powered on the recommended wiring diagram d Powering up the remote control board Figure 22 Remote control board power up recommended wiring diagram PIN PIN PIN PIN PIN PIN 24V light output indicator 24V Main power supply online indicator light ON OFF switch ...

Page 39: ... output the main control board power on the relay suction 4 4 2 Hard Wiring XP1 64 pin hard wire interface control signal input and output interface of laser in remote mode Input high level is greater than 18V valid input low level is less than 3V valid Specific interface definitions are shown in Table 7 below Table 7 XP1 Hardwire interface definitions No XP1 Interface Requirements Type Descriptio...

Page 40: ...atterns Input signal High level enables PC software control function A4 Reset signal Input signal High level effective clear laser alarm bit effective high level time at least 1 MS A5 Red light indicator Input signal The effective red light indicates light A6 Simulation control enabling energy Input signal The input signal can simulate the input signal Program num 0000000 A7 Stop programming Mode ...

Page 41: ...ndicating that the laser is emitting light B3 The laser operates in internal mode Output signal Output signal indicating that the laser operates in internal mode B4 Laser anomalies Output signal Output signal indicating Abnormal laser B5 Laser red light indication Output signal Output signal indicating that the laser is red B6 AD mode Output signal Output signal indicating that the laser operates ...

Page 42: ...er B14 Backup B15 External power supply positive The external 24 V input voltage all table output signal power supply only these two feet access 24 V power output signal is effective B16 Negative external power D1 D4 Current gate channel indication Output signal Output signal indicating the actual channel position of the current gate 0000 gate closed channel 0001 1 selected channel 0010 2 selected...

Page 43: ...GND Serial port public end 4 4 4 Analog Interface XP4 The analog interface an 8 core Harting interface is used to control the output power of the laser by analog in AD mode and can also monitor the output light and power feedback signals of the laser The interface definition is shown in Table 9 below Table 9 XP4 Analog interface definitions Pin No Type Description 1 IN 0 10 V analog signal laser p...

Page 44: ...laser cannot be turned on When one of the channels is open the laser main power supply is impossible to start until the other channel is open and then the two channels are closed before the laser main power supply can be started If the interlock is closed the stop button is also released and there is no error alarm press the start LASER button to start the main power supply and the main power has ...

Page 45: ... figure 24 Figure 24 Schematic diagram of the internal electrical circuit of the laser Note in the strong power control part contactor K1 and K2 of RFL C20000XZ laser its power part is 3 pieces 50A contactors in parallel use and signal end 6 in series use 4 7 Start operation sequence a Turn on the water cooler check whether the water pipe is leaking turn off the water cooler and connect electrical...

Page 46: ...ll laser doors are closed optical cable output head has been inserted into the cutting head or corresponding equipment all interlock interfaces have been closed e Select the required control mode according to 1 4 control mode turn on the key switch and start the main power supply waiting for the laser to ready When the laser is ready the green light comes in the tricolor above the machine represen...

Page 47: ...ser request is high XP1 A2 light output enable is high XP2 1 2 input MOD signal XP1 A1 A5is high level close enable enable determined by programming command XP1 A1 laser request is high XP1 A2 high level indicates operating programs XP1 A1 A5is high level 1 Communication sends DEC or computer software clicks button 2 Communication sends DLE or computer software clicks button 3 Communication sends ...

Page 48: ...r software clicks button to emit red light communication sends ABF or computer software clicks button to turn off the red light 13 The communication sends SDC XX to set the power percentage XX represents the power percentage or the computer software clicks button 2 5 1 ON Mode In the ON mode the user can send commands to set different working modes through computer software or direct communication...

Page 49: ...aser works by means of communication so there is a time delay of at least 10 MS when the red light is turned on and off When the red light is on the laser cannot be set to Ready position Only when the red light is off can the laser be ready this limit can be changed please contact Raycus Engineer 5 5 Programming Mode In the ON mode when the current program number of the laser is not 0 the laser wi...

Page 50: ...s of A2 xp2 1 and PIN 2 MOD signals of xP1 5 6 3 Red light control When both A1 and A3 of xP1 are set high the laser is in the red light internal control mode and the red light is controlled by the computer software red light button or communication to send ABN and ABF used to control the ON and OFF of the red light When A1 of xP1 is set high A3 is suspended or set low the laser is in external con...

Page 51: ...ration methods 1 Turn the knob switch of the rear panel to on 2 Turn the key switch to on 3 Open the computer software 4 Click the red light ON button to view the red light 5 Turn off AD mode and external control mode This mode can be memorized if power off 6 Click main power ON button 7 Wait for Ready 8 Set the light output parameters 9 Click laser on button ...

Page 52: ...cation in ON mode Operation methods 1 Turn the knob switch of the rear panel to ON 2 Turn the key switch to ON 3 Open the computer software 4 Click the red light ON button to view the red light 5 Turn off AD mode and turn on external control mode This mode can be memorized after power failure 6 Click main power ON button 7 Wait for Ready 8 Setting the light power percentage 9 Mod signal outputs hi...

Page 53: ...emission external control set by power analog on the ON mode Operation methods 1 Turn the knob switch of the rear panel to ON 2 Turn the key switch to ON 3 Open the computer software 4 Click the red light ON button to view the red light 5 Turn off AD mode and turn on external control mode This mode can be memorized after power failure 6 Click main power ON button ...

Page 54: ...signal 6 4 Emission external control through programming mode on the ON mode Figure 28 Wiring diagram of Emission external control through programming mode on the ON mode Operation methods 1 Turn the knob switch of the rear panel to ON 2 Turn the key switch to ON 3 Open the computer software 4 Click the red light ON button to view the red light ...

Page 55: ... The lifting edge of MOD signal starts wave Note high level time of MOD must be more than program operation if MOD gives the falling edge in advance the computer software will show that the laser program is stopped abnormally 6 5 Set the power analog as emission external control on the REM mode Figure 29 Wiring diagram of setting the power analog as emission external control on the REM mode ...

Page 56: ...5connects 24V and turn on red light XP1 A5 connects 0V after checking optics and turn off red light 6 XP1 C1connects 24V main power on You can also directly press the laser button or the main power ON button 7 Wait for Ready 8 XP1 A2 connects 24V and control board outputs analog and MOD signal Figure 30 timing diagram of setting power analog as emission external control signal on REM mode 6 6 REM ...

Page 57: ...operation methods 1 Turn the knob of the rear panel to ON button 2 Turn the key switch to REM 3 Short Pin8 Pin9 of XP2 4 XP1 A1connects 24V 5 XP1 A5 connects 24V and turn on the red light XP1 A5 connects 0V after checking optics and turn off red light 6 XP1 C1connects 24V main power supply powers on You can also directly press the laser button or the main power ON button ...

Page 58: ...oftware sets power XP1 A2 connects 24V control board outputs MOD signal 6 7 Programming mode in REM mode Figure 32 Wiring diagram of programming mode on REM mode Operation methods 1 Turn the knob switch of the rear panel to ON button 2 Turn the key switch to REM button 3 Short PIN8 PIN9 of XP2 4 XP1 A1 connects 24V ...

Page 59: ... ON button in the main power supply of the upper computer software 7 Wait for Ready button 8 XP1 A8 14 selects the pre executed program number and XP1 A2 sets high level to start operating the program Figure 33 Timing diagram of control signal of programming mode 7 RS232 and INTERNET Communication Command 7 1 Port Configuration RS 232 configuration is as follows baud rate 9600 data bit 8 stop bit ...

Page 60: ... value for each command received The return value generally contains the command content itself If the returned content contains a numeric value or contains an error type the returned command content is separated from the numeric value or from the error type The specific agreement content and command examples of this product are shown in Table 12 Table 12 Specific Protocol Contents and Command Exa...

Page 61: ...d SPRR 1000 r Return SPRR 1000 r ERR input Err r ERR Out of Range r ERR Duty Cycle too High r ERR Duty Cycle too Low r SPW 100 Duty 100 r SDC Set Diode Current The set value must be less than 100 and above the minimum current setting value which can be set to 0 If the set value is greater than 100 the default is input 100 Send SDC 100 r Return SDC 100 r Other return values ERR Input Err r Laser is...

Page 62: ...s corrected and output after filtering so the response time of AD analog is larger than that of through mode Send ECM r Return ECM r DCM Disable Calibration Mode AD analog response time is less than 100 us in this mode Send DCM r Return DCM r Others Command error Send BGM r Return Command Err r STA Read device status Read the product status A return value of 32 Bit digital information The meaning ...

Page 63: ...n Bit 6 Normal Sub controlling communication Abnormal Bit 7 Normal Sub module Abnormal Bit 8 Guide red light off Guide red light on Bit 9 The laser is not ready The laser is ready Bit 10 QCW mode off QCW mode on Bit 11 Module Main Power off Module Main Power on Bit 12 Modulation mode off Modulation mode on Bit 13 Normal Leakage sensors 1 leaking Bit 14 Normal Leakage sensors 2 leaking Bit 15 No la...

Page 64: ...off Wave mode on Bit 23 Surge protector Normal Surge protector failure Bit 24 normal Low temperature fault Bit 25 normal Humidity alarm Bit 26 normal Water flowmeter 1 Flow Alarm Bit 27 Red light internal control Red Light External Control Bit 28 normal Water flowmeter 2 Flow Alarm Bit 29 normal Module locked Bit 30 Optical circuit safety interlock normal Optical circuit safety interlock abnormal ...

Page 65: ...Ltd User Guide of RFL C20000XZ 58 8 1 Main interface of PC software The PC software s main interface is shown in Figure 34 Figure 34 PC software display main interface 8 2 Multi laser Control Area Multi laser control area is shown in Figure 35 ...

Page 66: ...lected laser After the communication established the lower left status display shows that the network connection is ok shown in Figure 36 Figure 36 communication status interface between PC software and laser 8 2 1 Add delete laser You can add delete laser in the laser list area by right click to add delete In the PC software You need to type the IP address of laser to add a new laser Detailed ope...

Page 67: ...Ltd User Guide of RFL C20000XZ 60 Figure 37 Procedure for adding a laser to the PC software 8 2 2 Modify laser IP After the laser connection has been established select the IP address of current laser and right click to set it up in Figure 38 ...

Page 68: ...Raycus Fiber Laser Technologies Co Ltd User Guide of RFL C20000XZ 61 Figure 38 Modify the IP address of laser 8 3 Main working status display The laser s main status display is as shown in Figure 39 Table 13 ...

Page 69: ...f Ready light Indicates readiness of current laser green laser is ready gray laser is not ready Alarm light indicates alarm status of current laser yellow laser is abnormal gray laser is normal Emission light indicates the working model of the current laser red laser is in working model gray laser is not in output model 8 3 1 Laser s cumulative operating time display area The laser s cumulative op...

Page 70: ...ks in external control mode Gray laser works in internal control mode Laser on off is controllable by software Power correction Green Laser operates in power linear correction mode in which control system automatically adjusts the laser s output power It makes the output power linear with a longer response time for AD analog in this mode longer than 1mS Gray laser operates in non correction mode a...

Page 71: ...ower up mode selection light out control display area is as in Figure 42 the display content is as in Table 15 Figure 42 Laser power on mode selection light out control display area Table 15 Laser power on mode selection light out control display area explanation Display Explanation Main power button Click ON main power on click OFF main power off External control mode Click ON activate laser exte...

Page 72: ...his function can only run internal mode when external mode is turned off Enter the current pre tested programming number in the digital text box and click the START button Figure 43 Laser programming mode test area display interface 8 3 5 Power slow rise down parameter setting area The interface of the laser power slow rise fall parameter setting area is shown in Figure 44 Click read parameter to ...

Page 73: ...wn in Figure 45 The output parameter setting is not valid when AD mode is on Figure 45 Laser output parameter setting area display interface 8 4 Laser parameter display area The display interface for laser parameter display area is shown in Figure 46 The module status is used to shield the faulty module the green light indicates the number of modules installed inside the current laser and the chec...

Page 74: ...47 This interface shows the cause of the alarm for the current laser Figure 47 Laser alarm type display area interface 8 6 PC software operating mode selection The laser operating mode is set by the PC software Its operating interface is show in Figure 48 The interpretation of the various patterns can be found in Table 16 The programming editing interface is displayed on the software only when pro...

Page 75: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of RFL C20000XZ 68 Figure 48 Laser operating mode selects the display area interface ...

Page 76: ... status and parameters for diagnosis purposes Authorization mode Time limited locking function can be set on laser Debug mode You can modify laser parameters subject to valid password 8 7 Language Laser s language selection interface is shown in figure 49 User can choose between simplified Chinese and English by clicking setting language Setting effective after PC software restarted Figure 49 Lang...

Page 77: ...8 8 2 Authorization on authorization mode The authorization settings in laser authorization mode are shown in Figure 51 This interface allows the customer to lock and unlock the machine and can also be used as an authorization code generator a The locking time setting can set the effective using time of laser b The terminal password is set for the laser locking party The terminal code can only be ...

Page 78: ...ime lock is achieved when user click again to set the authorization time Figure 51 Authorization settings operating interface on authorization mode 8 9 About Laser relevant information such as date of manufacture model serial number controlling serial number token version number system information and other information can be queried in the PC software about item Specific interface is shown in Fig...

Page 79: ...ant information query interface 8 10 XP1 interface status indication in diagnostic mode The laser interface status indicator interface is shown in Figure 53 It is convenient to view the interface status information which represents the input and output status of the XP1 interface on the back panel ...

Page 80: ... User Guide of RFL C20000XZ 73 Figure 53 The interface status in diagnostic mode 8 11 Log in diagnostic mode Laser s working log interface is shown in Figure 54 User can query work log by entering the time to query and click on the search button ...

Page 81: ... Raycus Fiber Laser Technologies Co Ltd User Guide of RFL C20000XZ 74 Figure 54 Laser s working log interface 8 11 1 Download log Log download interface is shown in Figure 55 Figure 55 Log download interface ...

Page 82: ...rface 8 11 3 Downloaded file address The file address query interface for all download information is shown in Figure 57 Figure 57 the file address query interface for all downloaded information 9 128 12 Module parameters in diagnostic mode Laser module parameter query interface is show in Figure 58 The interface is for the parameter query in diagnostic mode from which Raycus technicians can analy...

Page 83: ... Technologies Co Ltd User Guide of RFL C20000XZ 76 Figure 58 Module parameters query interface in diagnostic mode 9 138 13 Programming settings programming editing The laser programming settings interface is shown in Figure 59 ...

Page 84: ...r of wave bars inside the current laser Operating interfaces of viewing the number of wave bar stored inside the current laser is shown in Figure 60 The software automatically lists the number of wavelength bars that have been saved by clicking on the Refresher List button Green indicates the bar already has a program and white indicates that the bar is empty ...

Page 85: ... current laser 8 13 2 Check programming content To check the programming contents in the current laser programming mode is shown in Figure 61 The program automatically lists the original programming by clicking the programming number that needs to be checked Figure 61 Programming content interface in the current laser programming mode ...

Page 86: ...ing stored in the current laser programming mode 8 13 4 Edit Programming Programming editing when the laser is working in programming mode as shown in Figure 63 Step 1 left click the pre edited programming number Step 2 select the command under the command type click Add Step 3 enter the parameters and click Save The instruction appears in the left program list immediately Step 4 after editing all...

Page 87: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of RFL C20000XZ 80 a Select the pre edited programming number b add command type ...

Page 88: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of RFL C20000XZ 81 C save command d type the command code into laser ...

Page 89: ... Command meaning in laser working status is shown in Table 17 Table 17 command meaning in laser working status Code 1 Byte Parameter1 2 bytes Parameter 2 4 bytes Note 1 Stop none none The program end command the last command must be this command 2 SPT 0 65000 MS 0 65000 W Change power to 2 in time 1 3 SPR 0 65000 W MS 0 65000 W Change power to 2 in power change ratio 1 4 WAIT 1 Wait for sync signa...

Page 90: ...ignal high level output 7 EXT Power 1 0 10V 2 9 Warranty Repair and Return 9 1 General Warranty After all the products manufactured are delivered according to the order or specifications Raycus will guarantee the products to be free from any material and technical problems and ensure that they meet the specifications under Normal use 10 1 Raycus has the right to selectively repair or replace any p...

Page 91: ...panies WARNING It is the customer s responsibility to understand and follow operating instructions in this User Guide and specifications prior to operation failure to do so may void this warranty Accessories and fiber connectors are not covered by this warranty 9 3 Service and Repair This product has no built in parts for user maintenance so all maintenance should be carried out by Raycus technica...

Page 92: ...of RFL C20000XZ 85 The above product warranty and service terms of Raycus are for users reference only and the formal service and warranty contents are subject to agreement in the contract 2021 Wuhan Raycus Fiber Laser technologies Co Ltd All Rights Reserved ...

Reviews: