Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C20000XZ
20
① ②
③ ④
⑤
⑥
Figure 11 Front view of the panel
Note:
①
REM/OFF/ON
②
POWER
③
LASER
④
ALARM
⑤
STOP
⑥
INDICATOR LIGHT
REM/OFF/ON:
The key switch is the main control switch of the laser. Insert the key and turn it to
the "ON" position, the main control part of the laser is powered on, and the POWER light is on, Rotate to
the "REM" position, you need to close the Pin8 and Pin9 of the XP2 interface on the rear panel to achieve
remote power-on, and rotate to REM to activate the hard-wired control mode of the laser.
POWER:
Control power indicator, when the white indicator light is on, it means the main control
system is on.
LASER:
The power button of the laser main power supply has a green light indicator function. After
the laser main control system is powered on and all INTERLOCKs are detected as normal, press this
button, the laser main power supply is powered on, and the button lights up after the main power supply is
powered on.
ALARM
:
INTERLOCK alarm indication, the ALARM indicator lights up during the power-on
self-check on the control panel. After the self-inspection is completed, all INTERLOCK interfaces are
normally closed, and the ALARM indicator is off. During the operation of the laser, any INTERLOCK
failure will cause the indicator to light.