Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus RFL-A6000D~A12000D
25
Table 8 XP4 Analog interface definitions
Pin No
Type
Description
1
IN
0
~
10 V analog signal, laser power control signal in AD mode,
0
~
10 V corresponding to 0
~
100% output power
2
AGND
Pin 1’s reference
3
OUT
Optical power monitoring output
,
0V corresponds to 0% laser power output,8V
corresponds to 100% laser power output
4
Reference
Pin 3’s Reference
5
N/C
Back up
6
N/C
Back up
7,8
N/C
Back up
4.4.5 INTERNET Interface XP5
Table 9 XP5 Communication interface definitions
Pin
Function
Description
1
TX+
Date trans
2
TX-
Date transmission-
3
RX+
Date
4
N/C
-
5
N/C
-
6
RX-
Date Receive-
7
N/C
-
8
N/C
-
4.5 Introduction to Safety Interlock
Raycus’ product is designed with a safe interlocking loop, which is a two-channel system with
output monitoring and manual reset. When the safety interlocking circuit is open, the safety circuit will
disconnect the working power of the optical module, that is, the main power supply of the optical module.