Insert the plug at the end of the power cord into the socket marked "AC INPUT" on the rear panel.
Note that the plug has an anti-reverse connection function. After inserting it, use the lock to lock. The
plug and socket as shown in Figure 9.
Figure9 physical picture of power cord plugs and socket
The definition and parameter requirements of the AC input line interface are shown in Table 4.
Table 4 AC input line interface definition and parameter requirements
6kW laser AC input line interface definition and parameter requirements
Connector Tag
Interface definition
Logo
Wire diameter
Wire
color
Wire length
1
AC380V-L1
L1
4mm
2
Brown
15m
3
AC380V-L2
L2
4mm
2
Black
15m
5
AC380V-L3
L3
4mm
2
Gray
15m
PE
Protective
PE
4mm
2
Yellow
green
15m
8
~
12kW laser AC input line interface definition and parameter requirements
Connector tag
Interface definition
Logo
Wire diameter wire color
Wire length
1
、
2
AC380V-L1
L1
6mm
2
+6mm
2
Brown
15m
3
、
4
AC380V-L2
L2
6mm
2
+6mm
2
Black
15m
5
、
6
AC380V-L3
L3
6mm
2
+6mm
2
Grey
15m
PE
protective
PE
6mm
2
Yellow
green
15m