Maintenance
Air Cleaner
• Clean or replace the filter cartridges if the indicator (5)
is illuminated. Clean the outer air filter cartridge (Rayco
part number 800276) every 100 hours and replace it
every year.
• Unfasten the clamps (6) holding the end cap of the air
cleaner and remove. After replacing the cartridges),
replace the end cap of the air cleaner and lock the clamps
so that the dust ejector valve (7) is positioned as shown.
• Replace the inner safety filter cartridge (Rayco part
number 800277) every 600 hours, or with every other
air filter cartridge replacement.
• Discharge the dust ejector valve (7).
Perform this procedure more frequently under extremely
dusty or dirty conditions.
More information and instructions can be found in your Kubota
Engine Operator Manual.
Radiator / Coolant
Check to be sure the coolant level is between the hot and
cold markers on the reservoir (9). The coolant reservoir is
located inside the engine enclosure, to view this open the
access cover (8) by loosening the wing nut. If the coolant level
is too low, before adding more coolant, check all hoses and
radiator cap for any possible leaks. If leaks are discovered,
contact your local authorized service dealer to be serviced.
If the coolant level is too low due to evaporation, fill back to
level with only fresh, soft water.
5
6
7
NOTICE
During filling the coolant, air must be vented from
the engine coolant passages. The air vents by
jiggling the radiator’s upper and lower hoses.
DO NOT REMOVE THE RADIATOR CAP UNTIL
COOLANT TEMPERATURE IS BELOW ITS
BOILING POINT. THEN LOOSEN CAP SLIGHTLY
TO RELIEVE ANY EXCESS PRESSURE
BEFORE REMOVING THE CAP ENTIRELY.
NOTICE
The coolant expansion bottle & radiator level
should be checked daily.
NOTICE
Be sure to close the radiator cap securely. If the
cap is loose or improperly closed, coolant may leak
out and the engine could overheat.
NOTICE
Do not mix the different type or brand of L.L.C
8
9
10
Summary of Contents for RG55R
Page 27: ...RG55R Operation Service Maintenance 800 392 2686 27 Operation...
Page 58: ...RG55R Operation Service Maintenance 58 Hydraulic Schematic 805921...
Page 59: ...RG55R Operation Service Maintenance 800 392 2686 59 Hydraulic Schematic 805921...
Page 67: ...RG55R Operation Service Maintenance 800 392 2686 67 Specifications...