Manual No. 016-5032-004
13
Hydraulic System Installation
Install the Override Flow Switch
FIGURE 7.
Fittings and Transducers Installed in the Flow Switch
1.
Install the
-6
ORFS (M) to
-6
SAE O-Ring (M) straight adapter fittings in the ends of the flow switch (P/N
334-0003-085), one in an A port and one in a B port.
2.
Install pressure transducers into the remaining A and B ports.
Note:
It makes no difference in which ports the adapter fittings and pressure transducers are installed as
long as one of each is installed in an A port and the other is installed in a B port.
FIGURE 8.
Flow Switch Mounted on the Machine
3.
Mount the flow switch to the valve mounting bracket using the supplied M8 hex head bolt (P/N 311-0070-
044) and the 5/16” lock washer (P/N 313-1000-019).
Note:
The existing bolt in the selected mounting location will need to be removed.
Axle Mounting Location
(Bottom View)
Cab Mounting Location
(Left Side View)
Valve
Mounting
Bolts
Front of Machine
Front of Machine