![background image](http://html.mh-extra.com/html/raven/scs-660/scs-660_installation-and-service-manual_788841039.webp)
5
Manual No. 016-0159-845
33
Console Programming and Calibration
Changing Initial Console Programming
Occasionally it is necessary to make changes to the console programming after the initial programming is
complete. To make changes to the initial setup:
1.
Press SELF TEST and hold it for 30 seconds. The console’s display will flash the current program setting.
2.
Press ENTER to advance to the setting that needs to be changed.
3.
Press CE to change the variable to the desired setting.
4.
Complete the data entry by pressing ENTER.
5.
Repeat the steps above for each variable that needs to be changed.
Programming Additional System Data
Although it is not required for system operation, data may be entered in the VOL TANK and TIME submenus.
Vol Tank
1.
Press the VOL TANK button.
2.
Press ENTER.
3.
Enter the estimated volume of product in the tank.
4.
Press ENTER.
Note:
The VOL TANK variable will have to be updated each time the tank is refilled.
Time and Date
Note:
The system runs on a 24 hour clock. Therefore, for any time after 12:59 pm, add 12 hours to the
time. For example, 8:30 am is entered as 8:30, but 1:30 pm is entered as 13:30 on the keyboard.
1.
Press the TIME button. The message “RATE 0.0 TIME 0:00” will appear in the console’s display.
2.
Enter the time.
3.
Press ENTER.
4.
Use the arrow keys to toggle to the date fields (MONTH, DAY, YEAR) and enter the data for each of the
fields.
Power Down
If the console is not used for 10 days, it reverts to a power down (low power) mode by default. In this mode, all
data is retained, but the time of day clock will reset to 0:00. The default date may be changed from 10 days to
a number preferred by the user. To change the default power down value:
1.
Press the TIME button. The message “RATE 0.0 TIME 0:00” will appear in the console’s display.
1.
Use the arrow keys to toggle to POWER DOWN.
2.
Enter the desired default power down value (the number of days before the system clock is reset to 0:00).