4
Manual No. 016-0159-845
21
Installation
Console and Cabling Installation
Note:
The SCS 660 control console is designed to be used with external boom switches. Boom signal
wires are provided to communicate to the console which booms are turned ON and which are
turned OFF. The console recognizes that a boom is turned ON wh12 VDC is applied to
the boom signal wire. The boom signal wires must be connected to the switched side of the boom
valve.
1.
Mount the SCS 660 console to a secure area inside the machine’s cab.
Note:
The SCS 660 console should be mounted in the machine’s cab so that the machine operator has
easy access to it.
2.
Connect the female end of the console control cable into the back of the console.
3.
If using the Raven radar speed sensor:
•
Connect the red wire on the radar power cable to the orange cable wire on the console control cable.
•
Connect the white wire on the radar power cable to the white wire on the console control cable.
4.
Turn the POWER ON/OFF switch on the console to OFF.
5.
Route the red wire on the console control cable to the 12 VDC battery and connect it to the positive (+)
battery terminal.
6.
Route the white wire on the console control cable to the 12 VDC battery and connect it to the negative ( - )
battery terminal.
Important:
Do not connect the red and white wires to the machine’s starter!
7.
Secure the battery wires with zip ties.
Important:
Do not secure the battery wires near the existing battery leads or any other electrical wiring.
8.
Connect the speed sensor cable to the back of the console.
9.
Connect the male end of the console cable to the main female connector on the flow control cable.
10.
Secure the speed sensor cable and console control cable with zip ties.
CAUTION
Always connect the power cable as the last
step in the installation process and verify that
the power leads are connected with the correct
polarity. Reversing power leads can cause
severe damage to the equipment.