High Level Check
System Check
Remedy
Will not drive in reverse
Will not drive forward or in reverse
Generator switch is on. Unit not in neutral
100A battery fuse, 100A drive fuse, failed or
missing 48V battery
Test and verify all too solve issue.
Will not drive forward
Will not drive in reverse
Will not drive forward or in reverse
75A fuse, 100A fuse, 48V battery failed open
circuit, no 48V battery pack, 48V battery
connector or 48V battery lead open circuit
Drive system and mowing deck do not
operate, but generator works fine
75A fuse, 100A fuse, 48V battery failed open
circuit, no 48V battery pack, 48V battery
connector or 48V battery lead open circuit
Vehicle controller is powered by 12V starter
battery and performs a safety shut down
when the starter battery is low or defective.
Replace 12V battery or charge the battery if it
is simply low
30A fuse open and/or failure in the 12V
charging system
Drive is "jerky" in engine and/or mowing
mode
Rider weight
Seat switch
Drive is "jerky" on hills or rough terrain
Rider weight
Seat Switch
Transaxle in netrual
Drive gear in transmission is not fully engaged
Drive stops and starts while driving, as if the
motor is cutting out
Low 48VDC Large battery
Low 48V battery, Possible 48 pack failing
Drive has stopped working after operator
jump-started engine because of a dead
starter battery
No
D
riv
e i
n G
as
M
od
e
Dr
ive
Sy
st
em
-
O
th
er
Will not drive after changing gear from Low
to High or vice versa
Symptom
Will not drive forward
No
D
riv
e i
n
El
ec
tr
ic
M
ode
Summary of Contents for MPV-7100
Page 1: ...Raven 7100 Service Manual ...
Page 2: ...12v Battery Exchange ...
Page 4: ...12 Volt Relay Exchange ...
Page 6: ...48 Volt Battery Pack Removal ...
Page 8: ...Blade Motor Controllers ...
Page 11: ...Carburetor Replacement ...
Page 16: ...Contactor Fuse Replacement ...
Page 21: ...Drive Motor Controller Replacement ...
Page 27: ...Gas Gauge Check Replacement ...
Page 30: ...Oil Separator Replacement ...
Page 33: ...PCB Replacement ...